𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A critical investigation of the effects of the radio frequency potential on the trapping of externally injected ions in ion trap mass spectrometry

✍ Scribed by Damon B. Robb; Michael W. Blades


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
201 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


The sensitivity of all ion trap mass spectrometry (ITMS) methods is dependent on the trapping efficiency of the instrument. For ITMS instruments utilizing external ion sources, such as laser desorption, trapping efficiency is known to depend on the phase and amplitude of the radio frequency (RF) potential applied to the ring electrode at the time of ion introduction. It is remarkable that, in a considerable body of literature, no consensus exists regarding the effects of these parameters on the efficacy of trapping externally generated ions. In this paper, a summary of the literature is presented in order to highlight significant discrepancies. New laser desorption ion trap mass spectrometry (LD-ITMS) data are also presented, from which conclusions are drawn in our effort to clarify some of the confusion.


πŸ“œ SIMILAR VOLUMES


Investigation of the Mass Shifts Caused
✍ Wenjun Mo; John F. J. Todd πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 479 KB πŸ‘ 1 views

An ion-coupling model has been proposed to predict and interpret the occurrence of mass shifts induced by the presence of ions of other m/z ratios in the ion trap mass spectrometer. The method of dynamically scanning the dipolar tickle frequency has been used to determine the mass shifts for two spe

Origin of mass shifts in the quadrupole
✍ James Patrick Murphy III; Richard A. Yost πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 48 KB πŸ‘ 1 views

A novel hybrid tandem mass analyzer, coupling a quadrupole ion trap with a quadrupole mass filter, has been constructed to permit mass analysis of ions ejected from the ion trap. The initial application of this instrument is the investigation of the origin of mass shifts in the ion trap due to ion f

Windows version of the ion trap simulati
✍ Bui, Huy A.; Graham Cooks, R. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 215 KB πŸ‘ 1 views

The multi-particle simulation program ITSIM version 4.0 takes advantage of the enhanced performance of the Windows 95 and NT operating systems in areas such as memory management, user friendliness, Γ‘exibility of graphics and speed, to investigate the motion of ions in the quadrupole ion trap. New fe

Theoretical and numerical analysis of th
✍ Kiyomi Yoshinari πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 239 KB πŸ‘ 1 views

A numerical simulation method has been developed for the analysis of trapping ions injected into an ion trap mass spectrometer. This method was applied to clarify the effects of the following parameters on trapping efficiencies: (1) initial phase of the radio frequency (RF) drive voltage, (2) ion in

Structural studies of the Maillard react
✍ Tagami, Uno; Akashi, Satoko; Mizukoshi, Toshimi; Suzuki, Eiichiro; Hirayama, Kaz πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 145 KB πŸ‘ 1 views

The early stage products of the Maillard reaction of egg white lysozyme with D-glucose were studied. Incubation with D-glucose at 50 β€’ C for 20 days caused reaction on the Lys and Arg residues of lysozyme as follows: all of the six Lys residues and 10 of the 11 Arg residues in lysozyme reacted with

Investigating the use of an octupole ion
✍ Robert D. Voyksner; Heewon Lee πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 148 KB πŸ‘ 2 views

An octupole radio frequency (rf) ion guide was evaluated for storage and filtering of ions generated by electrospray prior to introduction into an ion trap mass spectrometer. The control of the rf potential on the ion guide enabled its operation as a high-pass mass filter, removing low-mass chemical