Oligonucleotides have become widely used tools in molecular biology and molecular diagnostics. Their parallel synthesis in large numbers and the increasing interest in microarray technology has raised the requirement for fast and informative analytical tools for their quality control. A direct injec
Negative Ionization Micro Electrospray Mass Spectrometry of Oligonucleotides and their Complexes
β Scribed by Michael J. Greig; Hans-J. Gaus; Richard H. Griffey
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 443 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
The utility of negative ionization micro electrospray (microspray) mass spectrometry is demonstrated for detection of oligonucleotides and their noncovalent complexes. A simple microspray ionization source is fabricated from an outer stainless-steel needle and an inner fused-silica capillary. Under these conditions, the liquid flow rate can be reduced 15-fold from 7.5 pL/min to 0.5 pL/min. Studies of a 14-mer DNA oligonucleotide show no change in the charge-state distribution and quantity of adducted salt ions during the microspray process compared to pneumatically assisted electrospray mass spectrometry. The microspray ion source is less sensitive to the presence of solution buffers, and an 11-fold increase in integrated ion abundance from oligonucleotide analyte is observed with a lOmM concentration of ammonium acetate, compared to pneumatically assisted nebulization (PAN). A >100-fold increase in the dup1ex:single strand ratio for a l4mer oligodeoxynucleotide and its complementary strand is observed using the microspray ion source relative to experiments performed with PAN. Studies of duplexes between DNA and a peptide nucleic acid suggest that this effect may be related to the degree of adduction of counterions to the DNA during ionization.
π SIMILAR VOLUMES
The magnesium, nickel, copper, zinc and vanadium metalloporphyrins from octaethylporphyrin, etioporphyrin I and tetraphenylporphyrin were characterized using electrospray ionization mass spectrometry (ESI-MS). The ion abundance of each of the porphyrins present in binary mixtures was monitored as a
An approach to enable negative ion electrospray ionization (ESI) mass spectrometric detection of analytes that lack acidic sites and thus exhibit weak [MΓH] Γ signals has been developed. The method relies upon attachment of Cl Γ ions present in electrosprayed solutions of chlorinated solvents such a
The effect of cone voltage on the polymer mass distribution of non-polar poly(styrene) samples has been investigated using electrospray ionization. It was found that relatively high cone voltages (120 V) were required to ionize non-polar polymers. At lower cone voltages (30-60 V), cluster ions, e.g.
A detailed study of the solution chemistry and mass spectrometry of six carboxylato-organogermanium compounds in aqueous solution has been carried out using electrospray ionization and MS n techniques. The different types of hydrolysis products and their probable structures, which include the oligom