𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Electrospray ionization mass spectrometry of organogermanium compounds

✍ Scribed by Junhua Wei; Ji Chen; Jack Martin Miller


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
235 KB
Volume
15
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A detailed study of the solution chemistry and mass spectrometry of six carboxylato-organogermanium compounds in aqueous solution has been carried out using electrospray ionization and MS n techniques. The different types of hydrolysis products and their probable structures, which include the oligomers and their fragment ions plus water adduct ions formed by ion-molecule reactions, are presented, e.g., HO-cyclic-(-

and Γ€ CH=CHGeO-cyclic-(-Ge(OH) CH 2 CH 2 COO) D, etc. The proposed cyclic structures are confirmed by theoretical calculations.


πŸ“œ SIMILAR VOLUMES


Electrospray ionization mass spectrometr
✍ Vandell, Victor E.; Limbach, Patrick A. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 373 KB πŸ‘ 1 views

The magnesium, nickel, copper, zinc and vanadium metalloporphyrins from octaethylporphyrin, etioporphyrin I and tetraphenylporphyrin were characterized using electrospray ionization mass spectrometry (ESI-MS). The ion abundance of each of the porphyrins present in binary mixtures was monitored as a

Electrospray Ionization Mass Spectrometr
✍ Christina B. Jasieczek; Armelle Buzy; David M. Haddleton; Keith R. Jennings πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 463 KB πŸ‘ 2 views

The effect of cone voltage on the polymer mass distribution of non-polar poly(styrene) samples has been investigated using electrospray ionization. It was found that relatively high cone voltages (120 V) were required to ionize non-polar polymers. At lower cone voltages (30-60 V), cluster ions, e.g.

Preparative mass spectrometry with elect
✍ Siuzdak, Gary; Hollenbeck, Thomas; Bothner, Brian πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 42 KB πŸ‘ 1 views

## Preparative Mass Spectrometry with Electrospray Ionization In the early 1940s, E. O. Lawrence developed a mass spectrometry-based separation approach to enrich radioactive uranium 235 U from the natural isotopic distribution of uranium. 1 -3 This method used Calutron 3 mass spectrometers to sep

Quantification of Glycated Hemoglobin by
✍ Nakanishi, Toyofumi; Miyazaki, Ayako; Kishikawa, Masahiko; Yasuda, Mamoru; Tokuc πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 323 KB πŸ‘ 2 views

Glycated hemoglobin, considered to be the best index for the treatment of diabetes mellitus, was measured by electrospray ionization mass spectrometry (ESI/MS) according to the method proposed by Morris et al. at the 44th ASMS Conference on Mass Spectrometry and Allied Topics, 1996. They compared th