The magnesium, nickel, copper, zinc and vanadium metalloporphyrins from octaethylporphyrin, etioporphyrin I and tetraphenylporphyrin were characterized using electrospray ionization mass spectrometry (ESI-MS). The ion abundance of each of the porphyrins present in binary mixtures was monitored as a
Electrospray Ionization Mass Spectrometry of Poly(styrene)
β Scribed by Christina B. Jasieczek; Armelle Buzy; David M. Haddleton; Keith R. Jennings
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 463 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
The effect of cone voltage on the polymer mass distribution of non-polar poly(styrene) samples has been investigated using electrospray ionization. It was found that relatively high cone voltages (120 V) were required to ionize non-polar polymers. At lower cone voltages (30-60 V), cluster ions, e.g. [M+2catI2+ and [ZM+cat]', were observed. Singly-charged species predominated only at high cone voltages, but no fragmentation of the oligomer ions has been seen. The molecular mass distributions obtained by electmpray ionization have been compared with those obtained by size-exclusion chromatography and the agreement (generally within 10%) has been shown to be cone-voltage dependent.
π SIMILAR VOLUMES
A detailed study of the solution chemistry and mass spectrometry of six carboxylato-organogermanium compounds in aqueous solution has been carried out using electrospray ionization and MS n techniques. The different types of hydrolysis products and their probable structures, which include the oligom
## Preparative Mass Spectrometry with Electrospray Ionization In the early 1940s, E. O. Lawrence developed a mass spectrometry-based separation approach to enrich radioactive uranium 235 U from the natural isotopic distribution of uranium. 1 -3 This method used Calutron 3 mass spectrometers to sep
Glycated hemoglobin, considered to be the best index for the treatment of diabetes mellitus, was measured by electrospray ionization mass spectrometry (ESI/MS) according to the method proposed by Morris et al. at the 44th ASMS Conference on Mass Spectrometry and Allied Topics, 1996. They compared th
Electrospray mass spectrometry was used to simultaneously determine aspartame (APM) and five of its degradation products; aspartic acid, aspartylphenylalanine, 5-benzyl-3,6-dioxo-2-piperazieacetic acid (diketopiperazine), phenylalanine, and phenylalanine methyl ester. Under the ionization conditions