MLPA: a rapid, reliable, and sensitive method for detection and analysis of abnormalities of 22q
β Scribed by J.A.S. Vorstman; G.R. Jalali; E.F. Rappaport; A.M. Hacker; C. Scott; B.S. Emanuel
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 307 KB
- Volume
- 27
- Category
- Article
- ISSN
- 1059-7794
No coin nor oath required. For personal study only.
β¦ Synopsis
In this study, essential test characteristics of the recently described multiplex ligation-dependent probe amplification (MLPA) method are presented, using chromosome 22 as a model. This novel method allows the relative quantification of approximately 40-45 different target DNA sequences in a single reaction. For the purpose of this study, MLPA was performed in a blinded manner on a training set containing over 50 samples, including typical 22q11.2 deletions, various atypical deletions, duplications (trisomy and tetrasomy), and unbalanced translocations. All samples in the training set have been previously characterized by fluorescence in situ hybridization (FISH) with cosmid or BAC clones and/or cytogenetic studies. MLPA findings were consistent with cytogenetic and FISH studies, no rearrangement went undetected and repeated tests gave consistent results. At a relative change in comparative signal strength of 30% or more, sensitivity and specificity values were 0.95 and 0.99, respectively. Given that MLPA is likely to be used as an initial screening method, a higher sensitivity, at the cost of a lower specificity, was deemed more appropriate. A receiver operator characteristic (ROC) curve analysis was performed to calculate the most optimal threshold range, with associated sensitivity and specificity values of 0.99 and 0.97, respectively. Finally, performance of each individual probe was analyzed, providing further useful information for the interpretation of MLPA results. In conclusion, MLPA has proven to be a highly sensitive and accurate tool for detecting copy number changes in the 22q11.2 region, making it a fast and economic alternative to currently used methods. The current study provides valuable and detailed information on the characteristics of this novel method.
π SIMILAR VOLUMES
We used a rapid and inexpensive method for studying the FMRl CGG-repeat from dried blood spots, prepared from heel pricks, finger pricks, or an aliquot of blood from a venipuncture. The procedure includes a single tube for preparation of template DNA for PCR and minimal handling, avoiding opportunit
A rapid and sensitive method for simultaneous detection of leukotriene (LT) B,, LTC,, LTD,, LTE,, 5S,12Sdihydroxy-eicosatetraenoic acid, 6-trans LTB,, 12-epi-6-trans LTB, and the w-metabolites of LTBl has been developed. Leukocyte incubations were terminated by the addition of one volume of methanol
## Abstract A fast and specific method for the detection of collagenase by electrophoresis is described. The method avoids inclusion of the substrate in the resolving gel and can detect nanogram levels of the enzyme.
A rapid and simple gas-liquid chromatographic method for the determination of subnanomolar amounts of carbohydrates derived from glycoproteins is described. The procedure involves methanolysis in the presence of methyl acetate followed by removal of hydrogen chloride by c~va~ration with t-butyl alco