๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Matrix-assisted Laser Desorption/Ionization by Two Collinear Subthreshold Laser Pulses

โœ Scribed by Xiaodong Tang; Mehrnoosh Sadeghi; Zohra Olumee; Akos Vertes


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
151 KB
Volume
11
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


Two nitrogen laser pulses of subthreshold irradiance were used to achieve matrix-assisted laser desorption/ionization in a collinear configuration. Optimum laser pulse delay times yielding maximum guest ion intensities were determined for four different matrices between 4.2 ns for sinapinic acid (SA) and 12.5 ns for 2,5-dihydroxybenzoic acid (DHB). The signal decay times followed an opposite trend to the position of maxima, DHB being the fastest decaying (1.1 ns) and SA the slowest (9.8 ns). Collinear subthreshold experiments allow for a two orders of magnitude improvement in spatial and time resolution over post-ionization experiments.


๐Ÿ“œ SIMILAR VOLUMES


Compact Tunable Cr:LiSAF Laser for Infra
โœ Mehrnoosh Sadeghi; Zohra Olumee; Xiaodong Tang; Akos Vertes; Zhi-Xing Jang; Angu ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 105 KB ๐Ÿ‘ 2 views

A tunable Cr:LiSAF laser-pumped optical parametric oscillator was used for mid-infrared matrix-assisted laser desorption/ionization (MALDI) mass spectrometry experiments. The mass spectra of substance P, bovine insulin and pd(T) 10 in the 2.88-2.96 ยตm range showed excellent single shot signal qualit

Ionization Modelling of Matrix Molecules
โœ D. A. Allwood; P. E. Dyer; R. W. Dreyfus ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 498 KB ๐Ÿ‘ 2 views

A scheme of matrix ionization in UV matrix-assisted laser desorptiodionization is presented. Excitation to an upper lying electronic singlet state by the absorption of two photons and subsequent thermionic emission by vibronic coupling is proposed as the primary route for the formation of unprotonat

Coupling matrix-assisted laser desorptio
โœ Kermit K. Murray ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 339 KB

This review discusses the off-line and on-line coupling of matrixspray ionization (ESI) (Fenn et al., 1990) have revolutionassisted laser desorption/ionization (MALDI) mass spectrometry to ized the mass spectrometric analysis of large molecules. liquid chromatography (LC) and capillary electrophore

Matrix-assisted laser desorption/ionizat
โœ N. I. Taranenko; V. V. Golovlev; S. L. Allman; N. V. Taranenko; C. H. Chen; J. H ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 155 KB ๐Ÿ‘ 2 views

Matrix-assisted laser desorption/ionization was used for the detection of four base short tandem repeats (STR) for clinical samples using a time-of-flight mass spectrometer. Since STR plays an important role in genetic disease and human identification, this work indicates that laser desorption mass

Chemical reactivity in matrix-assisted l
โœ C. Enjalbal; B. Sauvagnat; F. Lamaty; R. Lazaro; J. Martinez; P. Mouchet; F. Rou ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 139 KB ๐Ÿ‘ 2 views

During the control of a multistep organic synthesis on a soluble polymer (PEG) by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, a chemical reactivity was encountered when the matrix was acidic, for the samples where the amino moiety of the anchored compounds was protected as