𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic sector-ion trap mass spectrometry with electrospray ionization for high sensitivity peptide sequencing

✍ Scribed by Joseph A. Loo; Helmut Muenster


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
126 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A hybrid mass spectrometer composed of a high resolution double focusing instrument (electrostatic analyzer-magnetic sector, EB) and an ion trap analyzer (T) exhibits high sensitivity performance for peptide sequencing with electrospray ionization (ESI). MS 2 and MS 3 experiments for multiply charged tryptic peptides and larger peptides (e.g., melittin, 2.8 kDa) generate sequence-informative product ions. Collisionally activated dissociation (CAD) of selected precursor ions can also be performed in the interface between the double focusing analyzer and the ion trap (transfer octapole region) to generate product ions. With a low-flow micro-ESI source, which can deliver analyte solution to the source at a flowrate of 10-200 nL/min, tandem mass spectra can be obtained from sub-fmol amounts of melittin. The high resolving power of the MS-I stage combined with the efficiency of the ion trap stage allows for high resolution precursor ion selection with subsequent highly sensitive tandem mass spectrometry (MS/MS) analysis.


πŸ“œ SIMILAR VOLUMES


High-sensitivity analysis and sequencing
✍ Marina, Anabel; GarcΓ­a, Miguel Angel; Albar, Juan Pablo; YagΓΌe, JesΓΊs; LΓ³pez de πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 203 KB πŸ‘ 2 views

This paper describes experience with the commercially available LCQ quadrupole ion trap mass spectrometer applied to the o †-line analysis of peptides and proteins. The standard front end of the electrospray probe was replaced with a micromanipulator which, with the aid of a magnifying device, allow

Differentiation of lysine/glutamine in p
✍ U. Bahr; M. Karas; R. Kellner πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 248 KB πŸ‘ 2 views

Electrospray ionization coupled to a quadrupole ion trap mass spectrometer is used to differentiate between the isobaric amino acids lysine and glutamine in sequence analysis of peptides. Collision-induced dissociation is used for fragmentation. Several isobaric peptides with one or more lysines or

High performance liquid chromatography c
✍ Adriano Marcelli; Donata Favretto; Pietro Traldi πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 183 KB πŸ‘ 2 views

## Two (methoxymethyl)melamine resins of industrial and commercial interest have been analysed by means of high performance liquid chromatography (HPLC)/electrospray ionization ion trap mass spectrometry in order to identify the components of the complex mixtures which are produced by melamine res

On-line derivatization of peptides for i
✍ M. S. CΓ‘rdenas; E. van der Heeft; A. P. J. M. de Jong πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 152 KB πŸ‘ 2 views

An on-line method has been developed for the derivatization and coupled liquid chromatography (LC)/electrospray ionization (ESI) MS analysis of peptides at the femtomol level. Peptides are reacted with N-succinimidyl-2(3-pyridyl)acetate (SPA) in buffered aqueous medium at pH 7 following loading on a

Evaluation of high performance liquid ch
✍ Pierre-HervΓ© Lambert; Jean A. Boutin; Sophie Bertin; Jean-Luc FauchΓ¨re; Jean-Pau πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 132 KB πŸ‘ 2 views

Liquid chromatography/electrospray mass spectrometry with selected-ion monitoring makes possible the visualization and positive identification of a family of isobaric ions from libraries comprising hundreds of peptides. For larger libraries (up to 10 5 peptides), a given peptide, known to be unique

Positive ion electrospray ionization tan
✍ Robert L. St. Claire III πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 107 KB πŸ‘ 1 views

A novel analytical procedure has been developed for the analysis of intracellular nucleotide triphosphates. Positive ion electrospray ionization tandem mass spectrometry (MS/MS) was interfaced to ion-pairing highperformance liquid chromatography (HPLC) utilizing a mobile phase containing 10 mM ammon