Liquid chromatography-electron ionization mass spectrometry: Fields of application and evaluation of the performance of a Direct-EI interface

✍ Scribed by Achille Cappiello; Giorgio Famiglini; Pierangela Palma; Antonella Siviero


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
291 KB
Volume
24
Category
Article
ISSN
0277-7037

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct‐EI interface are described in this review. Direct‐EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer. Thanks to the reduced liquid intake and an in‐source nebulizer, the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC‐MS system can be converted into an LC‐MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non‐volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro‐PAH, and endocrine‐disrupting compounds, allowing picogram level detection and the possibility to record library‐matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation. © 2005 Wiley Periodicals, Inc., Mass Spec Rev 24:978–989, 2005


📜 SIMILAR VOLUMES


New trends in the application of electro
✍ Achille Cappiello; Giorgio Famiglini; Filippo Mangani; Pierangela Palma 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 444 KB

## Abstract | I. | Introduction | 88 | | II. | Cap‐EI Interface | 90 | | | A.   Interface Performance | 92 | | III. | Direct‐EI Interface | 93 | | | A.   Interface Performance | 97 | | IV. | Conclusions | 103 | | Acknowledgments | 103 | | References | 103 | Two recent approaches for coupling cap

Liquid chromatography-mass spectrometry
✍ M. A. Baldwin; F. W. McLafferty 📂 Article 📅 1973 🏛 John Wiley and Sons 🌐 English ⚖ 146 KB

## Abstract Mass spectra of solutes can be obtained by direct introduction of the solution into a chemical ionization source. This should facilitate direct monitoring of the effluent from liquid chromatography columns with nanogram sensitivity.

An eluent–jet interface for chemical ion
✍ Reyer J. Dijkstra; Ben L. M. Van Baar; Charles E. Kientz; Wilfried M. A. Niessen 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 190 KB 👁 2 views

An improved eluent-jet interface was used to combine flow-injection analysis (FIA) and micro-column liquid chromatography (LC) on-line with mass spectrometry (MS) in the electron ionization (EI) and solvent-independent chemical ionization (CI) modes. Good results were obtained for a series of pestic

Evaluation of the sensitivity of miniatu
✍ Martijn Kranendijk; Joop C. M. Waterval; Govert W. Somsen; Gerhardus J. de Jong 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 453 KB

## Abstract LC‐ESI‐MS is applied frequently in pharmaceutical analysis. The sample amount is generally not restricted, however with LC‐ESI‐MS, a lack of sensitivity may still be observed with standard‐bore LC columns in isocratic mode. Therefore, it was investigated whether increased sensitivity co

High Performance Liquid Chromatography/A
✍ Philip A. Clarke; Karen A. Barnes; James R. Startin; Frank I. Ibe; Martin J. She 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 393 KB 👁 2 views

The performance of electrospray ionization and atmospheric pressure chemical ionisation (APCI) for the analysis of carotenoids was investigated. On our instrument, APCI produced spectra which were readily interpreted, and the positive-ion mode proved applicable to all of the compounds. The separatio