๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Evaluation of the sensitivity of miniaturized liquid chromatography-electrospray ionization-mass spectrometry for pharmaceutical analysis

โœ Scribed by Martijn Kranendijk; Joop C. M. Waterval; Govert W. Somsen; Gerhardus J. de Jong


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
453 KB
Volume
28
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

LCโ€ESIโ€MS is applied frequently in pharmaceutical analysis. The sample amount is generally not restricted, however with LCโ€ESIโ€MS, a lack of sensitivity may still be observed with standardโ€bore LC columns in isocratic mode. Therefore, it was investigated whether increased sensitivity could be achieved by using miniaturized LCโ€ESIโ€MS. Seven columns ranging from 0.1 to 4.6 mm ID were tested using several instrument setups. For proper comparison, a sensitivity gain factor (SGF) was introduced. The SGF expresses the extra sensitivity that may be obtained on top of the normal increase of peak concentration, which can be expected when the column ID is reduced. Desogestrel, mirtazapine, and sugammadex sodium were used as test compounds. For desogestrel and sugammadex sodium, the SGF increased up to a factor of 5โ€“13 when the column ID was reduced, indicating enhanced ionization efficiencies at lower flow rates. Optimum sensitivity was found for the 0.3 mm column coupled in combination with a microinjection valve and a dedicated low flow rate interface. For mirtazapine, no increase of SGF was observed when the column ID was decreased. Apparently, the ionization efficiency of this compound is not affected by the flow rate and the spray quality.


๐Ÿ“œ SIMILAR VOLUMES


Analysis of Phosphorylated Terpenes by E
โœ Iris Ney; Elke Jรคger; Markus Herderich; Peter Schreier; Wilfried Schwab ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 362 KB ๐Ÿ‘ 2 views

Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of

Two-dimensional analysis of phospholipid
โœ Ryo Taguchi; Jun Hayakawa; Yumi Takeuchi; Mayuko Ishida ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 380 KB ๐Ÿ‘ 2 views

A phospholipid mixture extracted from cultured cells was directly analyzed by capillary (Cap) liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS). Using a quadrupole mass spectrometer, we analyzed positive molecular ions, negative molecular ions, positive fragment ions an

Structural analysis of chromophore-label
โœ Li, D. T.; Her, G. R. ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 296 KB ๐Ÿ‘ 2 views

Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteris

Packed capillary liquid chromatography/e
โœ M. Arthur Moseley III; Steve E. Unger ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 342 KB

## Abstract The coupling of packed capillary liquid chromatography with electrospray ionization mass spectrometry has yielded an instrument capable of generating molecular weight information from very complex natural protein mixtures. The use of the packed capillary liquid chromatography columns of

Development of a sensitive liquid chroma
โœ Kazuo Yamaguchi; Michio Takashima; Tatsuo Uchimura; Satoshi Kobayashi ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 69 KB ๐Ÿ‘ 2 views

A sensitive method for the determination of a prokinetic peptide, KW-5139 (Leu 13 -motilin), in rat plasma has been developed utilizing liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). KW-5139 was separated by reversed-phase HPLC, with a mixture of 75 mM ammonium formate

Analysis of metal complex azo dyes by hi
โœ Karel Lemr; Michal Holcฬ†apek; Pavel Jandera; Antonรญn Lycฬ†ka ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 152 KB ๐Ÿ‘ 2 views

Five metal complex azo compounds were analyzed using negative-ion electrospray ionization mass spectrometry (ESI-MS). Mass spectra of all compounds yield intense peaks corresponding to [M - H](-) ions without any fragmentation, where M denotes the neutral compound with a proton as the counterion. Un