𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Liquid chromatographic method for the determination of sirolimus in blood using electrochemical detection

✍ Scribed by Nobuo Mochizuki; Etsuko Suka; Kunihiro Matsumoto; Osamu Akimoto; Keiko Ohno; Tsuyoshi Shimamura; Hiroyuki Furukawa; Satoru Todo; Satoshi Kishino


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
212 KB
Volume
23
Category
Article
ISSN
0269-3879

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Determination of sirolimus in rabbit art
✍ Jun Zhang; Ramona Rodila; Pamela Watson; Qin Ji; Tawakol A. El-Shourbagy πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 223 KB

## Abstract Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration stand

A high-performance liquid chromatographi
✍ Ladislav Ε oltΓ©s; ZoltΓ‘n KΓ‘llay; Ε tefan Bezek; Viera FedelesΗ’vΓ‘ πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 303 KB πŸ‘ 2 views

A high-performance liquid chromatographic method was developed to determine stobadin pharmacokinetics in dog and man. The relative bioavailability of stobadin dipalmitate compared with dihydrochloride was 46.4 per cent in dog. In man peak serum concentrations ranged from 12 to 289 ng ml-1 after a si

A liquid chromatographic method for the
✍ F. T. Delbeke; M. Debackere πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 245 KB πŸ‘ 1 views

A high performance liquid chromatographic method to measure plasma and urine fenoprofen levels in equine biofluids is described. Liquid-liquid extraction with diethylether was used to isolate the drug from plasma and urine. The accuracy and reproducibility of the method were within acceptable limits

High-performance liquid chromatographic
✍ Hui Wang; Guan Ye; Yi-Hong Tang; Hai-Yan Zhu; Rong-Rong Ma; Zhao-Ling Sun; Cheng πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 174 KB πŸ‘ 1 views

A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and

RP-HPLC method with electrochemical dete
✍ Henryk Lamparczyk; Aleksandra Chmielewska; Lucyna Konieczna; Alina Plenis; PaweΕ‚ πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 82 KB

## Abstract A rapid and sensitive reversed‐phase high performance liquid chromatographic method has been developed for the determination of metoclopramide in serum. The assay was performed after single extraction with ethyl ether using methyl parahydroxybenzoate as internal standard. Chromatographi