The purpose of this study was to develop an analytical method for evaluating the dissolution behavior of plasmasprayed hydroxyapatite (HAP) coatings. Six commercially available and clinically used coatings applied to nonporous titanium coupons according to their respective specifications for orthope
In vivo comparison of the osseointegration of vacuum plasma sprayed titanium- and hydroxyapatite-coated implants
✍ Scribed by Aebli, Nikolaus ;Krebs, J�rg ;Stich, Hermann ;Schawalder, Peter ;Walton, Mark ;Schwenke, Daryl ;Gruner, Heiko ;Gasser, Beat ;Theis, Jean-Claude
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 536 KB
- Volume
- 66A
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
For the last 15 years, orthopedic implants have been coated with hydroxyapatite (HA) to improve implant fixation. The osteoconductive effect of HA coatings has been demonstrated in experimental and clinical studies. However, there are ongoing developments to improve the quality of HA coatings. The objective of this study was to investigate whether a rough and highly crystalline HA coating applied by vacuum plasma spraying (VPS) had a positive effect on the osseointegration of special, high‐grade titanium (Ti) implants with the same surface roughness. Ti alloy implants were coated (VPS) with special, high‐grade Ti or HA. The osseointegration of the implants was evaluated by either light microscopy or pullout tests after 1, 2, and 4 weeks of unloaded implantation in the cancellous bone of 18 sheep. The interface shear strength increased significantly over all time intervals. By 4 weeks, values had reached ∼10__N__/mm^2^. However, the difference between the coatings was not significant at any time interval. Direct bone–implant contact was significantly different between the coatings after 2 and 4 weeks, and reached 46% for Ti and 68% for HA implants by 4 weeks. This study indicates that the use of a rough and highly crystalline HA coating, applied by VPS, enhances early osseointegration. Accelerated establishment of secondary implant fixation decreases the risk of early loosening. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 356–363, 2003
📜 SIMILAR VOLUMES
## Abstract The clinical use of plasma‐sprayed hydroxyapatite (HA) coatings on metal implants has been widely adopted because the HA coating can achieve the firmly and directly biological fixation with the surrounding bone tissue. However, the long‐term mechanical properties of HA coatings has been
This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurityphases, and indi
## Abstract The geometric design and chemical compositions of an implant surface may have an important part in affecting early implant stabilization and influencing tissue healing. In this study, __in vivo__ behavior and mechanical stability in implants of three surface designs, which were smooth s
The purpose of this study was to compare hydroxyapatite (HA)-coated titanium (Ti) and HAcoated cobalt-chrome (CoCr) implants in the distal femur of the rabbit by evaluating bone apposition and interfacial shear strength. Bilateral cylindrical implants with a plasma sprayed 50-jm thick HA coating wer