The aim of this study was to investigate the biological and mechanical response of bone to titanium plasmasprayed implants of different roughnesses. Three types of titanium plasma-spray coating were applied to beamshaped implants: Ti2, Ti3, and Ti4, with a Ra of 16.5, 21.4, and 37.9 m, respectively.
In vitro andin vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: The effect of coating characteristics
β Scribed by Yang, C. Y. ;Lin, R. M. ;Wang, B. C. ;Lee, T. M. ;Chang, E. ;Hang, Y. S. ;Chen, P. Q.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 646 KB
- Volume
- 37
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurityphases, and indices-of-crystallinity were used. In vitro testings were done by measuring the bonding-strength at the Ti-6Al-4V-HAC interface, with HACs that had and had not been immersed in a pH-buffered, serum-added simulated body fluid (SBF). The shear-strength at the HAC-bone interface was investigated in a canine transcortical femoral model after 12 and 24 weeks of implantation. The results showed a bonding degradation of approximately 32% or higher of the original strength after 4 weeks of immersion in SBF, and this predominantly depended on the constructed microstructure of the HACs. After the push-out measure-ments, it was demonstrated that the HACs with higher bonding-strength in vitro would correspondingly result in significantly higher shear-strength at each implant period in vivo. Nevertheless, there were no substantial histological variations between the two types of HACs evaluated. The most important point elucidated in this study was that, among coating characteristics, the microstructure was the key factor in influencing the mechanical stability of the HACs both in vitro and in vivo. As a consequence, a denser HAC was needed to ensure mechanical stability at both interfaces.
π SIMILAR VOLUMES
## Abstract The geometric design and chemical compositions of an implant surface may have an important part in affecting early implant stabilization and influencing tissue healing. In this study, __in vivo__ behavior and mechanical stability in implants of three surface designs, which were smooth s
## Abstract Skeletal bone consists of hydroxyapatite (HA) [Ca~10~(PO~4~)~6~(OH)~2~] and collagen type I, both of which are osseoconductive. The goal of osseointegration of orthopedic and dental implants is the rapid achievement of a mechanically stable longβlasting fixation between bone and an impl
The aim of this study was to investigate the bone response to calcium phosphate (Ca-P) plasma-spray and radiofrequency magnetron sputter-coated implants with comparable roughness. Therefore, tapered conical screw designed implants were installed in the trabecular bone of the femurs of nine goats. Th
## Abstract Several experiments were performed to compare the __in vitro__ adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)βbased polymer. The inclusion of various types of serum at different st
The response of bone of low density to uncoated, fluorapatite 6-month implantation periods. In addition, probably due to (FA), hydroxyapatite (HA), and hydroxyapatite heat treated the wide inter-and intra-animal variability, no significant (HAHT) plasma-sprayed coated implants was investigated diffe