Degradation potential of plasma-sprayed hydroxyapatite-coated titanium implants
β Scribed by Paschalis, E. P. ;Zhao, Q. ;Tucker, B. E. ;Mukhopadhayay, S. ;Bearcroft, J. A. ;Beals, N. B. ;Spector, M. ;Nancollas, G. H.
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 590 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
The purpose of this study was to develop an analytical method for evaluating the dissolution behavior of plasmasprayed hydroxyapatite (HAP) coatings. Six commercially available and clinically used coatings applied to nonporous titanium coupons according to their respective specifications for orthopedic devices were used in this study. Dissolution behavior was monitored by first preconditioning the implant in 0.15 mol L-' sodium chloride solution at 37Β°C until either equilibrium or the desired change in solution hydrogen and calcium ion concentrations had been reached. In the second step, the implants were subjected to dual constant composition (DCC) dissolution under condi-tions of controlled undersaturation. Results indicate that the dissolution rates of the HAP coatings may differ by as much as a factor of 5 despite the fact that analytical techniques, including X-ray diffraction and FTIR, indicate no change in crystallinity or composition of the coatings before and after the solution treatment. These results indicate that HAP coatings from different sources react very differently when placed in the same local aqueous environment. However, more work will be necessary before these in uitro results can be used to predict in vzuo behavior.
π SIMILAR VOLUMES
## Abstract For the last 15 years, orthopedic implants have been coated with hydroxyapatite (HA) to improve implant fixation. The osteoconductive effect of HA coatings has been demonstrated in experimental and clinical studies. However, there are ongoing developments to improve the quality of HA co
An intramedullary implant model in the canine femora was developed to evaluate the mechanical and histological responses between cancellous bone and plasma-sprayed hydroxyapatite coatings (HACs) on Ti-6A1-4V implants, with 12-and 24-week follow-ups. HACs of different thicknesses were investigated. R
This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurityphases, and indi
## Abstract We have established the electrical polarization method of hydroxyapatite (HA) coatings (HAC) for clinical use, such as dental and orthopedic implants. The HAC examined in the current study was prepared in titanium substrates by plasma spraying of Ξ²βtricalcium phosphate (TCP) powders fol