## Abstract Heparin immobilization chemistry using alkyl spacer arms was adapted to optimize yield on polyurethane (PU) surfaces. The resultant biological activity of immobilized heparin (HI) was examined __in vitro__ and __in vivo__, and compared with a heparin releasing (HR) system. Immobilized h
In vitro andin vivo metal ion release
β Scribed by Brown, Stanley A. ;Farnsworth, Lilian J. ;Merritt, Katharine ;Crowe, Timothy D.
- Publisher
- John Wiley and Sons
- Year
- 1988
- Tongue
- English
- Weight
- 954 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
A series of experiments was conducted to study in vitro and in vivo metal ion release and the urine excretion of metal ions. Metal salts were injected and urine analyzed. Anodic potentials were applied to stainless steel and cobalt-chromium-molybdenum (CCM) specimens to cause an acceleration of corrosion rates. Corrosion experiments were done in saline, 10% serum and in a subcutaneous space in hamsters. Corrosion rates were determined by measurements of weight loss and calculations of net charge transfer. Metal ion concentrations were determined with graphite furnace atomic absorption spectroscopy, and were calcu-lated from total charge using Faraday's law. The results with stainless steel showed that the weight loss and metal ion release from stainless steel ii7 &ro and in vim can be calculated using Faraday's Law, assuming release in proportion to alloy composition. The results with CCM indicated that release rates in vifm can be used to determine the proportionality of release iri zlivo. All the nickel and most of the cobalt was rapidly excreted, while less than 50% of the chromium was excreted. The excretion of metals following salt injection or in oioo corrosion were very similar.
π SIMILAR VOLUMES
## Abstract The flexural strength, microstructure and relative Ca and Si concentration at the surface of two commercial orthopedic aluminas were studied before and after aging up to 52 weeks in simulated body fluids or in subcutaneous implantation in rodents. There was no significant reduction in f
## Abstract Polyesteranhydrides synthesized by the transesterification of ricinoleic acid and sebacic acid followed by anhydride polymerization were examined as potential controlled delivery carrier for paclitaxel. Solid and liquid polymers were used. Polymers containing 30% ricinoleic acid are sol
Heparin was covalently coupled to collageno-elastic grafts (CET) derived from lamb carotid arteries, by u s i n g t h e crosslinking agent 1-ethyl-3 (3-dimethylaminopropyl) carbodiimide (EDC). The collagenous grafts were pretreated with various aminating agents in order to enhance the number of avai
## Abstract The __in vitro__ and __in vivo__ degradation of polyβLβlactic acid cages used as an adjunct to spinal arthrodesis was investigated. In the __in vitro__ experiments cages were subjected to aging up to 73 weeks in phosphateβbuffered solution (pH 7.4) at 37 Β°C. Inherent viscosity, crystall