A method is presented that converts dynamic T 1 -weighted spoiled gradient-recalled echo (SGRE) image intensities into estimates of T 1 without the errors associated with imperfections in the slice profile and transmitter coil magnetic field (B 1 ). The method involves T 1 measurements performed bef
Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements
✍ Scribed by Greg O. Cron; Frederick Kelcz; Giles E. Santyr
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 185 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Dynamic contrast‐enhanced breast MR imaging was performed on 14 patients (five cancerous lesions, nine benign) with slice‐selective spoiled gradient‐recalled echo (2D SPGR) imaging. Adiabatic saturation recovery T~1~ measurements were performed before (T~1pre~) and after (T~1post~) 2D SPGR imaging. These two “bookend” T~1~ measurements were used to calibrate the equations which were employed to convert the time course of the 2D SPGR signal strength to T~1~‐vs.‐time, which in turn was used to compute the gadolinium concentration‐vs.‐time (C) in the lesion. The extraction‐flow product (EF) was computed for each lesion by pharmacokinetic modeling of C. For this study, EF provided a sensitivity and specificity for cancer of 100% and 78%, respectively. When only T~1pre~ was used to estimate C (which assumes a priori knowledge of the shape and amplitude of the slice profile), the sensitivity and specificity fell to 80% and 56%, respectively. This is presumably due to unexpected variations in the shape and/or amplitude of the slice profile, which could be caused by factors such as patient‐to‐patient variations in breast geometry or inconsistently set transmit gains. Therefore, both T~1pre~ and T~1post~ measurements are necessary for optimum sensitivity and specificity using pharmacokinetic analysis. Magn Reson Med 51:1066–1070, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
A multiparametric computer-aided diagnosis scheme that combines information from T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2-weighted MRI was investigated using a database of 110 malignant and 86 benign breast lesions. Automatic lesion segmentation was performed, and three categories of l
## Abstract Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because
## Abstract Breakdown of the blood‐brain barrier (BBB), occurring in many neurological diseases, has been difficult to measure noninvasively in humans. Dynamic contrast‐enhanced magnetic resonance imaging measures BBB permeability. However, important technical challenges remain and normative data f