✦ Synopsis


Abstract

A micro‐scale liquid chromatography electrospray ionization tandem mass spectrometric method was developed for the identification of polymerized impurities in ampicillin and amoxicillin in aqueous solution. Ampicillin and amoxicillin are broad‐spectrum antibiotics and widely used for the treatment of human and animal infections. In this study ampicillin, amoxicillin, and their dimers were trapped in a 5‐cm capillary column containing C~18~ sorbents. The analytes were separated on a reversed‐phase column and introduced into the mass spectrometer via a nanospray ion source. An isocratic mobile phase consisting of 1% formic acid‐acetonitrile (50 : 50, v/v) was used. For identification, the fragment ions of the analytes were monitored. The aim of the present study was to develop an optimized quality control method for the analysis of high molecular weight impurities of ampicillin and amoxicillin.


📜 SIMILAR VOLUMES


Identification and Mapping of Phosphocho
✍ J. M. McMahon; R. T. Short; C. A. McCandlish; J. T. Brenna; P. J. Todd 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 638 KB

Secondary ion mass spectra and images were obtained from animal tissue samples using less than 10(13) primary ions/cm2. The mass spectra showed abundant peaks at m/z 184 and m/z 86. Tandem mass spectrometry (MS/MS) was used to identify the source of these ions as phosphocholine. Secondary ion images

Direct identification of yessotoxin in s
✍ Rosa Draisci; Luigi Giannetti; Luca Lucentini; Emanuele Ferretti; Luca Palleschi 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 145 KB 👁 2 views

A new method for the direct identification of yessotoxin (YTX), a polyether compound belonging to the diarrhoeic shellfish poisoning (DSP) toxins, using liquid chromatography coupled with mass spectrometry and tandem mass spectrometry (LC/MS and LC/MS/MS) is reported. Full-scan ionspray mass spectra

Characterization of industrial alkylpoly
✍ Silvia Ortega-Gadea; Virginia Bernabé-Zafón; Ernesto F. Simó-Alfonso; Christophe 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 217 KB 👁 1 views

## Abstract Technical grade diethylene‐triaminepentakis(methylenephosphonic acid) (I), dihexamethylene‐triaminepentakis(methylenephosphonic acid) (II), ethylene‐diaminetetrakis(methylenephosphonic acid) (III), hexamethylene‐diaminetetrakis(methylenephosphonic acid) (IV), amino‐tris(methylenephospho

Rapid identification of saponins in plan
✍ Meng Cui; Fengrui Song; Yu Zhou; Zhiqiang Liu; Shuying Liu 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 127 KB 👁 2 views

Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural in