𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow injection determination of metrifonate by immobilised acetylcholinesterase inhibition

✍ Scribed by T. Ghous; A. Townshend


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
552 KB
Volume
332
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A flow injection system for determination of metrifonate by inhibition of immobilised acetylcholinesterase (AChE) is described. Acetylthiocholine is hydrolysed by AChE, and the thiocholine produced is mixed with the chromogen 5,5dithiobis(2-nitrobenzoic acid) and the absorbance is measured at 405nm. The decrease in absorbance due to decrease in enzymatic activity after injecting metrifonate as an inhibitor is measured. On-line re-activation of the inhibited enzyme by buffer, substrate and pyridine-2-aldoxime methiodide is also studied so that system can be reused continuously. The calibration graph is linear in the range of 1 x 10e6 to 1 x lo-' M metrifonate (~0.998, n=5), the 3a limit of detection is 8x lop7 M and the relative standard deviation for 5 determinations of 6x 10e6M metrifonate is 2.0%. Common blood components did not interfere.


πŸ“œ SIMILAR VOLUMES


Studies on the inhibition of immobilised
✍ J. Marcos; Alan Townshend πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 788 KB

Inhibition of immobilized alkaline phosphatase by several metal ions and EDTA was studied in a single-channel flow-injection system. The enzyme was immobilised on controlled pore glass. The same enzyme preparation was used for three months. The inhibition by the tested compounds is reversible, the i

Flow-injection determination of kanamyci
✍ Abdulrahman A. Alwarthan; Saad A. Al-Tamrah; Akel A. Akel πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 616 KB

The application of lucigenin chemiluminescence for the determination of trace concentrations of kanamycin i described. The method is based on the inhibiting effect that kanamycin has on the reaction of lucigenin an hydrogen peroxide in a basic solution. The effect of the concentrations of the reagen

Determination of paraquat by flow-inject
✍ Archana Jain; Krishna K. Verma; Alan Townshend πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 472 KB

The solution obtained by oxidizing some of the ascorbic acid to dehydroascorbic acid by reaction with potassium iodate is used as a reagent for the reduction of paraquat to a blue radical cation in the flow-injection spectrophotometric determination of paraquat. A rectilinear calibration graph was o

Flow-injection spectrophotometric determ
✍ L.Lahuerta Zamora; J.MartΓ­nez Calatayud πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 396 KB

The flow-injection spectrophotometric determination of different amino acids was carried out by reaction with copper(B) ions entrapped in a polymeric material and filling a packed-bed reactor; the released copperW, complexed with the amino acid, reacted with zincon in a basic medium producing a blue

Characterisation of inhibitors of acetyl
✍ Alexander GΓΌnther; Ursula Bilitewski πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 702 KB

Acetylcholinesterase was immobilised on magnetic particles and integrated in a flow-injection system via a magnetic reactor. Enzyme activity was determined amperometrically using acetylthiocholine chloride as enzyme substrate. This system was applied to enzyme inhibition tests. Inhibition constants