𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of three procedures for the estimation of serum digoxin levels

✍ Scribed by M. Givner; R. Gaudet; S. Wakkary; D. Ryder; S. Boss; M. Moss; C. Jacklyn


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
104 KB
Volume
26
Category
Article
ISSN
0009-9120

No coin nor oath required. For personal study only.

✦ Synopsis


Prior to GC-MS analysis, samples (1 mL) were passed through a C-18 SPE cartridge (Supelco) preconditioned with ethyl acetate, 96% (v/v) ethanol and 10% (v/v) ethanol in sequence. Resveratrol was eluted with ethyl acetate and 1 mL was collected of which 1 I~L was injected. For samples with very low concentration, the eluate was dried and reconstituted in 200 I~L ethyl acetate. The method gave the following performance characteristics: sensitivity 10 pg on injection or 10 p.p.b, in sample; CV within-batch 1.7%-5.7%; CV day-to-day <8%; quantitative recovery (-100%); linearity 10-40 p.p.b, for human urine and 60-300 p.p.b, for human serum. The method should have wide application in clinical, pharmacological and industrial investigations and is the first step in a program to develop formulations containing resveratrol (food, wine or pharmaceuticals) for human consumption.


πŸ“œ SIMILAR VOLUMES


Digoxin levels in the serum of healthy n
✍ A. Malamitsi-Puchner; B. Thanopoulos; M. Christophoraki; E. Constantellou; E. Pa πŸ“‚ Article πŸ“… 1986 πŸ› Springer 🌐 English βš– 250 KB
Evaluation of three methods for estimati
✍ Lyndon M. Hill; Robert Breckle; Kim R. Wolfgram; Peter C. O'Brien πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 English βš– 675 KB

Three ultrasonic methods for estimating fetal weight (Campbell, Warsof, and Shepard) were compared in 124 singleton pregnancies. Fetal abdominal circumference was obtained by use of a map measurer and from diameter measurements and the equation for the circumference of a circle. Campbell's formula f

Evaluation of three assays for the deter
✍ M. Crook; M. Haq; P. Tutt πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 371 KB

There is increasing clinical interest in the measurement of serum total sialic acid (TSA). There are a number of methods available but with little data suggesting the preferred technique. We evaluated three serum sialic acid assays: the Warren assay, the Svennerholm assay, and a commercially availab

Evaluations of maximization procedures f
✍ Swati Biswas; Shili Lin πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 142 KB

## Abstract Locus heterogeneity is a major problem plaguing the mapping of disease genes responsible for complex genetic traits via linkage analysis. A common feature of several available methods to account for heterogeneity is that they involve maximizing a multidimensional likelihood to obtain ma

Evaluation of serum autoantibody levels
✍ Yu-Chiao Yi; Shih-Chi Wang; Chun-Chin Chao; Chia-Ling Su; Yao-Ling Lee; Ling-Yun πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 156 KB

## Abstract __Objective__: We analyzed autoantibodies against tumor‐associated antigens (TAAs) in the serum of patients with endometrioma and healthy controls to determine whether autoantibodies can be accurate biomarkers for the diagnosis of ovarian endometrioma. __Methods__: Serum samples were o