𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Enantiomeric separation of amino acids and nonprotein amino acids using a particle-loaded monolithic column

✍ Scribed by Masaru Kato; Maria T. Dulay; Bryson Bennett; Jing-ran Chen; Richard N. Zare


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
106 KB
Volume
21
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Enantiomeric separation of dansyl amino
✍ Nils G. Sundin; Thomas M. Dowling; Nelu Grinberg; Gary Bicker πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 675 KB

Enantiomeric separation of 11 dansyl amino acids is reported using micellar electrokinetic capillary chromatography. The chiral phase consisted of a copper complex of N , N-di-decyl-D-alanine dissolved in the running buffer. Several factors affecting the separation were studied. The partitioning of

Chemically L-prolinamide-modified monoli
✍ Zilin Chen; Toshiyuki Hobo πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 120 KB πŸ‘ 2 views

Chemically L-prolinamide-modified monolithic silica column for enantiomeric separation of dansyl amino acids and hydroxy acids by capillary electrochromatography and Γ¬-high performance liquid chromatography A silica-based chiral monolithic column prepared by sol-gel process and chemical modification

Enantiomeric separation of five amino ac
✍ FranΓ§ois Gimenez; Mireille Soursac; Robert Farinotti πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 129 KB πŸ‘ 2 views

A chiral liquid chromatographic method was validated to analyze the Dand L-enantiomers of five amino acids contained in a commercial solution: aspartic acid, leucine, lysine, phenylalanine, and valine. These 10 compounds were separated on a chiral crown ether column with a mobile phase composed of w

Determination of amino acids by gas chro
✍ Moodie, I. M. ;Burger, J. A. ;Labadarios, D. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 429 KB πŸ‘ 2 views

A procedure is described in whicha wide borecapillarycolumn is used as an alternative to the more traditional packed column for the quantitative analysis of amino acids as their N-heptafluorobutyryl isobutyl ester (HBB) derivatives. Thecolumn, installed in a gas chromatograph previously configured f

A comparative study of HPLC and TLC sepa
✍ R. Bhushan; Imran Ali; Shalini Sharma πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 266 KB πŸ‘ 2 views

Separation of amino acids using Cu(I1) by RP-HPLC and impregnated TLC is reported. For IIPLC the sample mixture of amino acids containing copper (11) was injected into the column while for TLC the silica gel plates were impregnated with Cu(I1). The mobile phase used in I1PLC was acetate buffer (0.3