𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Differentiation of hepatocellular carcinoma and hepatic metastasis from cysts and hemangiomas with calculated T2 relaxation times and the T1/T2 relaxation times ratio

✍ Scribed by Steven W. Farraher; Hernán Jara; Kevin J. Chang; Al Ozonoff; Jorge A. Soto


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
310 KB
Volume
24
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To determine the diagnostic capability of the T1 and T2 relaxation times and the T1/T2 relaxation times ratio generated with the mixed turbo spin echo (mixed‐TSE) pulse sequence, in order to discriminate between hepatocellular carcinoma (HCC)/metastases and hemangiomas/cysts.

Materials and Methods

A retrospective review of 36 MR examinations implementing the mixed‐TSE pulse sequence demonstrated 70 focal hepatic lesions. Quantitative MR algorithms were used to generate T1 and T2 relaxation times, and the T1/T2 relaxation times ratio for each lesion. A two‐sample t‐test compared mean T1 and T2 relaxation times, and the T1/T2 relaxation times ratio, by lesion type: carcinoma/metastases and hemangiomas/cysts. Sensitivity and specificity for discriminating carcinoma/metastases from hemangiomas/cysts with T2 relaxation time thresholds of 112 and 125 msec, as well as a ratio of T1/T2 relaxation times of 5.8, were calculated.

Results

Using a T2 relaxation time threshold of 112 msec, 92% sensitivity and 100% specificity discriminating cysts/hemangiomas from HCC/liver metastasis was demonstrated. With a threshold of 125 msec, 96% sensitivity and 98% specificity was demonstrated. There was no correlation between calculated T1 relaxation times and type of lesion. Using a T1/T2 relaxation times ratio of 5.8, 100% sensitivity and specificity were demonstrated.

Conclusion

Although there is high sensitivity and specificity associated with the use of T2 relaxation times alone to discriminate carcinoma/metastases from hemangiomas/cysts, using the T1/T2 relaxation times ratio threshold of 5.8 allowed proper classification of all lesions. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Differentiation of hepatic malignancies
✍ Eric W. Olcott; King C.P. Li; Graham A. Wright; Philip P. Pattarelli; Douglas S. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 128 KB 👁 2 views

The purpose of this study was to examine hepatic lesions with a sequence designed to yield improved T2 measurements and evaluate the clinical utility of these measurements in distinguishing malignant from benign disease. Using a modified Carr-Purcell sequence incorporating features designed to compe

Differentiation between hemangiomas and
✍ Wei Li; Michael A. Nissenbaum; Michael K. Stehling; Alexander Goldmann; Robert R 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 396 KB

## Abstract The authors studied the utility of non‐contrast‐agent‐enhanced magnetic resonance (MR) imaging for differentiating cysts and cavernous hemangiomas of the liver. Nineteen patients with hemangiomas (51 lesions) and 16 with cysts (30 lesions) were studied with a 1.5‐T MR imager. T2 values

Quantitative measurements of proton spin
✍ David N. Guilfoyle; Victor V. Dyakin; Jacqueline O'Shea; Gaby S. Pell; Joseph A. 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 382 KB 👁 1 views

The goal of this work is to provide regional T(1) and T(2) values at a field strength of 7 T for the normal mouse brain at 6 weeks and 1 year old. A novel segmented snapshot FLASH sequence was used to measure T(1) in the hippocampus, corpus callosum, and the retrosplenial granular (RSG) cortex; T(2)

Ultrashort TE MR imaging of bovine corti
✍ Nima Kokabi; Won Bae; Eric Diaz; Christine B. Chung; Graeme M. Bydder; Jiang Du 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 459 KB

The effects of water loss on the T 1 and T 2 \* of bovine cortical bone were investigated using ultrashort echo time sequences with signals excited either by a short hard pulse or by two longer half pulses. Nine bovine femur samples were prepared and sequentially air-and oven-dried. On average 3.42%

Effects of the interaction between ferri
✍ Jeffrey M. Tosk; Barbara A. Holshouser; Roland C. Aloia; David B. Hinshaw Jr.; A 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 398 KB

## Abstract T1 and T2 relaxation times of agar phantoms containing L‐dopa melanin and Fe^3+^ were measured under MRI conditions. Fe^3+^ shortened T1 and T2 relaxation times. Melanin influenced relaxation times only in the presence of Fe^3+^; thus, contrast in MR images of the basal ganglia may depe