The purpose of this study was to examine hepatic lesions with a sequence designed to yield improved T2 measurements and evaluate the clinical utility of these measurements in distinguishing malignant from benign disease. Using a modified Carr-Purcell sequence incorporating features designed to compe
Differentiation between hemangiomas and cysts of the liver with nonenhanced MR imaging: Efficacy of T2 values at 1.5 T
✍ Scribed by Wei Li; Michael A. Nissenbaum; Michael K. Stehling; Alexander Goldmann; Robert R. Edelman
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 396 KB
- Volume
- 3
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The authors studied the utility of non‐contrast‐agent‐enhanced magnetic resonance (MR) imaging for differentiating cysts and cavernous hemangiomas of the liver. Nineteen patients with hemangiomas (51 lesions) and 16 with cysts (30 lesions) were studied with a 1.5‐T MR imager. T2 values were calculated with the two‐point method to evaluate the efficacy of T2 values in the differentiation between hemangiomas and cysts of the liver. For lesions larger than 1 cm, the mean T2 value of cysts (306 msec ± 156) was significantly longer than that of hemangiomas (113 msec ± 15) (P < .0001); there was no overlap of the ranges for T2 values of hemangiomas and cysts. All cysts larger than 1 cm could be differentiated from hemangiomas by using a threshold T2 value of 140 msec. This study suggests that calculated T2 values permit differentiation between hemangiomas and cysts larger than 1 cm at 1.5 T.
📜 SIMILAR VOLUMES
## Abstract The authors reviewed their 21/2‐year experience with a magnetic resonance (MR) imaging protocol for a 1.5‐T MR imager that included T2‐weighted fat‐suppressed spin‐echo, T1‐weighted breath‐hold gradient‐echo, and serial dynamic gadolinium‐enhanced T1‐weighted gradient‐echo imaging to id
## Abstract ## Purpose To determine the diagnostic capability of the T1 and T2 relaxation times and the T1/T2 relaxation times ratio generated with the mixed turbo spin echo (mixed‐TSE) pulse sequence, in order to discriminate between hepatocellular carcinoma (HCC)/metastases and hemangiomas/cysts
## Abstract Three magnetic resonance (MR) imaging techniques (T1‐weighted, T2‐weighted, and T1‐weighted gadopentetate dimeglumine—enhanced) were compared in 32 consecutive MR imaging studies of 26 patients with suspected musculoskeletal masses. T2‐weighted images were superior to T1‐weighted enhanc
## Abstract ## Purpose To compare 3.0T and 1.5T MR systems in terms of the effect of superparamagnetic iron oxide (SPIO) on tumor‐to‐liver contrast in T2\*‐weighted gradient‐echo MRI. ## Materials and Methods SPIO‐enhanced gradient‐echo MR images of the liver with four different TEs (3, 5.3, 6.5