Abstract
A computer program has been developed for evaluating the NMR signal response of various imaging parameters and its efficiency in fat suppression of the RODEO (ROtating Delivery of Excitation Offโresonance) pulse sequence. Both spoiled and refocused RODEO pulse sequences have been considered. By numerically solving the Bloch equation modified for a threeโdimensional volume of spins, for realistic RF excitations and Lorentzian distribution of the frequency spectrum for both fat and water, the program permits the imaging contrast and fat suppression of the RODEO pulse sequences to be assessed quantitatively. We have found that excellent fat suppression can be achieved by choosing appropriate imaging parameters. Imaging contrast for different tissues can be enhanced by using longer repetition time (TR) in the spoiled scheme. The complex pattern of the NMR signal response and imaging contrast has been observed in the refocused scheme.
๐ SIMILAR VOLUMES
## Abstract This article describes a methodology for determining the precision of a recently published method for quantitative water content mapping using MRI. A framework for calculating the random error component as a function of sequence parameters is provided and predictions are compared with e
The quinolone antibacterial agent cinoxacin was studied by adsorptive stripping voltammetry making use of its controlled interfacial accumulation on a static mercury drop electrode. Measurements were obtained in differential pulse mode and optimized by experimental design. The chemometric approach a
Many linear image restoration methods minimize a compound criterion which balances some fidelity to the observed data via a least-squares measure, and some fidelity to prior information on the unknown object via a smoothing function. In the case of quadratic criteria, this regularization scheme can