𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of misoprostol free acid in human breast milk and serum by gas chromatography/negative ion chemical ionization tandem mass spectrometry

✍ Scribed by Bernhard Watzer; Hannsjörg W. Seyberth; Horst Schweer


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
142 KB
Volume
37
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

To study an expected transition of misoprostol from human blood into breast milk, a novel method for the determination of its active metabolite misoprostol acid (MPA) was developed. MPA was determined in serum and breast milk samples by an isotope dilution assay using gas chromatography/negative ion chemical ionization tandem mass spectrometry (GC/NICI‐MS/MS). After addition of (15__S__)‐15‐methylprostaglandin E~2~ (15‐methyl‐PGE~2~) as an internal standard, MPA was extracted from both matrices using a reversed‐phase cartridge. The prostanoids were derivatized with O‐2,3,4,5,6‐pentafluorobenzylhydroxylamine hydrochloride (PFBHA) and 2,3,4,5,6‐pentafluorobenzyl bromide (PFBB) to the pentafluorobenzyl oxime (PFBO)‐pentafluorobenzyl ester (PFB) derivatives. The sample was subjected to thin‐layer chromatography with ethyl acetate–hexane (1 : 1 (v/v)) as the developing solvent. The corresponding zone was extracted. After derivatization to the trimethylsilyl ether, MPA was determined by GC/NICI‐MS/MS using the [molecule (M) − pentafluorobenzyl (PFB)]^−^ ([P]^−^) ions as precursor in the negative ion chemical ionization mode. The product ions used for quantification were [P − 2TMSOH − C~6~F~5~CH~2~OH]^−^ (MPA) and [P − 2TMSOH − C~6~F~5~CH~2~OH − CO~2~]^−^(15‐methyl‐PGE~2~), respectively. The limit of quantification for MPA was ∼1 pg ml^−1^ in breast milk and serum samples. The correlation coefficients of the calibration curves for MPA were r > 0.997 in the 0.5–2000 pg ml^−1^ range for both tested matrices. Copyright © 2002 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Determination of anabolic steroids by ga
✍ Man Ho Choi; Bong Chul Chung; Won Lee; Un Chul Lee; Yunje Kim 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 118 KB 👁 2 views

A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),

Determination of Cortisol in Human Plasm
✍ F.F. Hsu; L.H. Wang; D.M. Bier 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 296 KB

We report an isotope dilution mass spectrometry method using capillary gas chromatography negative ion chemical ionization for the determination of cortisol in human plasma. Cortisol was derivatized with pentafluoropropionic anhydride at room temperature and measured by selected ion monitoring of th

Determination of four anabolic steroid m
✍ Man Ho Choi; Bong Chul Chung; Myungsoo Kim; Jeongeun Choi; Yunje Kim 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 2 views

A gas chromatography/mass spectrometry method is described which uses negative ion chemical ionization and tandem mass spectrometry for the determination of anabolic steroid metabolites. Four anabolic steroid metabolites to be derivatized by Pentafluoropropionic anhydride (PFPA) were determined usin

Quantitative determination of nitroglyce
✍ Pekka Ottoila; Jyrki Taskinen; Aslak Sothmann 📂 Article 📅 1982 🏛 John Wiley and Sons 🌐 English ⚖ 265 KB 👁 2 views

A quantitative method for determination of nitroglycerin in human plasma was developed. Nitroglycerin and the internal standard (butane-1,2,4-triyl trinitrate) were extracted from plasma with pentane. The extracts were analysed by gas chromatography mass spectrometry using fused silica capillary col

Determination of Alprazolam and α-Hydrox
✍ Höld, Karin M.; Crouch, Dennis J.; Rollins, Douglas E.; Wilkins, Diana G.; Canfi 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 567 KB

A sensitive and specific method was developed for the determination of alprazolam and its major metabolite a-hydroxyalprazolam in plasma. After the addition of deuterium-labeled internal standards, plasma samples were buffered to pH 9 with 1 ml of saturated sodium borate buffer, extracted with tolue