The spatial distribution of the ion cyclotron orbit 'guiding centers' (magnetron radii) in a Penning trap determines virtually all aspects of Fourier transform ion cyclotron resonance (FIICR) mass spectrometry performance. Here, we demonstrate experimentally a simple method for determining that distribution, based on measuring FMCR mass spectral peak height following dipolar excitatioddipolar detection at various stages of magnetron radial expansion. No instrumental modificaitions are needed. Such data will make it possible to evaluate theoretical models of space charge and to quantitate and optimize ion formation, ion injection, ion trapping, ion transfer, photodissodation and ultrahigh-nmlution JTICR experiments.


πŸ“œ SIMILAR VOLUMES


252Cf plasma desorption fourier transfor
✍ S. K. Viswanadham; D. M. Hercules; R. R. Weller; C. S. Giam πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 205 KB πŸ‘ 2 views

The ions produced by "'Cf plasma desorption are detected by Fourier transform ion cyclotron resonance techniques. Results for CsI and N,N,N-trimethyl-p-aminophenolate iodide show the feasibility of the technique with high resolution (up to 11 000 at m / z 23) and good signal-to-noise ratio (up to 72

Fourier Transform Ion Cyclotron Resonanc
✍ Christopher L. Hendrickson; Jared J. Drader; David A. Laude; Shenheng Guan; Alan πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 378 KB πŸ‘ 2 views

We present Fourier transform ion cyclotron resonance (FTICR) mass spectra at a magnetic field of 20 T; more than twice the highest field previously used for FTICR. Our instrument is based on a resistive magnet installed at the National High Magnetic Field Laboratory. The magnet has a 50mm diameter b

Advantages of High Magnetic Field for Fo
✍ Alan G. Marshall; Shenheng Guan πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 488 KB πŸ‘ 2 views

It is well-known that mass resolving power in Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) can increase linearly with increasing applied magnetic field induction, B. Here, we show that eight other FTICR primary performance parameters theoretically also increase linearly (qu

Electrospray ionisation Fourier-transfor
✍ Sally-Ann Poulsen; Paul J. Gates; Graham R. L. Cousins; Jeremyβ€…K. M. Sanders πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 97 KB πŸ‘ 2 views

The use of electrospray ionisation Fourier-transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) for the analysis of dynamic combinatorial libraries (DCLs) of pseudo-peptide macrocyclic hydrazone oligomers is presented. The design of library building blocks results in mixtures