In this work, we demonstrate tandem mass spectrometry on an ion trap storage-reflectron time-of-fight mass spectrometer (IT/reTOFMS). Ion isolation and activation were achieved by resonant excitation using multi-and single-frequency waveforms generated from an analog circuit. Product-ion spectra of
Detection of Oligonucleotides by External Injection into an Ion Trap Storage/Reflectron Time-of-flight Device
โ Scribed by Ling He; Yan-Hui Liu; Yongdong Zhu; David M. Lubman
- Book ID
- 101238507
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 218 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
The detection of oligonucleotides has been studied using external injection of Matrix-assisted laser desorption/ionization (MALDI) produced ions into a quadrupole ion trap storage device. The ions stored in the trap are then detected by pulsed DC ejection into a reflectron time-of-flight mass spectrometer. It is shown that by using a low acceleration voltage from the probe tip and external injection into the trap that 3-mers to 9-mers can be stored for 20-50 ms and detected as intact ions. In comparison, direct MALDI inside the trap resulted in extensive fragmentation as a function of storage time. Using the external injection method with a He buffer gas in the trap yields a resolution of 250-400 in the ion trap storage/reflectron time-of-flight mass spectrometer.
The resolution can be further enhanced to 400-800 using a bipolar extraction method. In addition, the trapping efficiency for the injection of externally produced ions into the trap can be enhanced using a dynamic trapping method. The MALDI mass spectra produced by this methodology result in excellent signal-to-noise ratio due to the capabilities of the trap for eliminating low mass matrix background from the spectra.
๐ SIMILAR VOLUMES
In this work we have developed a PC-based simulation to study ion injection, cooling and extraction processes for multiple ions in an ion trap/reflectron time-of-flight (IT/reTOF) system. This simulation is based upon SIMION 6.0 with user written programs in which a 3D collision model is used to des
Packed-capillary high-performance liquid chromatography (HPLC) was successfully coupled with an ion trap storage/reflectron time-of-flight mass spectrometer (LC/IT/reTOFMS) through an electrospray ionization interface for protein structural elucidation. Using the total-ion storage capabilities of th
Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) ฮฒ-chain. The Hb ฮฑ-and ฮฒ-chains are separated and
A data system based upon a 200MHz transient recorder interface card in a Pentium PC computer is demonstrated for on-line analysis of microbore high-performance liquid chromatography (HPLC), capillary HPLC and capillary electrophoresis (CE) separations using a fast and sensitive ion-trap storage/refl