Abstract

A series of cationic, zwitterionic and anionic fluorinated carbocyanine dyes, spin‐coated on Si substrates, were measured with time‐of‐flight static secondary ion mass spectrometry (TOF‐S‐SIMS) under Ga^+^ primary ion bombardment. Detailed fragmentation patterns were developed for all dyes measured. In the positive mode, the resulting spectra showed very intense signals for the precursor ions of the cationic dyes, whereas the protonated signals of the anionic dyes were hardly detected. Differences of three orders of magnitude were repeatedly observed for the secondary ion signal intensities of cationic and anionic dyes, respectively. All measured dyes yielded mass spectra containing several characteristic fragment ions. Although the secondary ion yields were still higher for the cationic than the anionic dye fragments, the difference was reduced to a factor of ≤10. This result and the fact that M^+^, [M + H]^+^ or [M + 2H]^+^ are even‐electron species make it very likely that the recorded fragments were not formed directly out of the (protonated) parent ions M^+^, [M + H]^+^ or [M + 2H]^+^. In the negative mode, none of the recorded spectra contained molecular information. Only signals originating from some characteristic elements of the molecules (F, Cl), the anionic counter ion signal and some low‐mass organic ions were detected. A comparative study was made between TOF‐S‐SIMS, using Ga^+^ primary ions, and other mass spectrometric techniques, namely fast atom bombardment (FAB), electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization (MALDI). The measurements showed that MALDI, ESI and FAB all give rise to spectra containing molecular ion signals. ESI and FAB produced M^+^ and [M + H]^+^ signals, originating from the cationic and zwitterionic dyes, in the positive mode and M^−^ and [M − H]^−^ signals of the anionic and zwitterionic dyes in the negative mode. With MALDI, molecular ion signals were measured in both modes for all the dyes. Structural fragment ions were detected for FAB, ESI and MALDI in both the positive and negative modes. Compared with the other techniques, TOF‐S‐SIMS induced a higher degree of fragmentation. Copyright © 2005 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Biological tissue imaging with time-of-f
✍ Alain Brunelle; David Touboul; Olivier Laprévote 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 873 KB

## Abstract Time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS) using liquid metal ion guns (LMIGs) is now sensitive enough to produce molecular‐ion images directly from biological tissue samples. Primary cluster ions strike a spot on the sample to produce a mass spectrum. An image of this sa

Static time-of-flight secondary ion mass
✍ Michaeleen L. Pacholski; Donald M. Cannon Jr.; Andrew G. Ewing; Nicholas Winogra 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 704 KB

The study of cell membrane lipid and steroid composition and distribution is important for the understanding of membrane dynamics and function. Here we present efforts to chemically image phospholipid distributions on a submicron scale on freeze-fractured and frozen-hydrated liposomes and red blood

Time-of-flight static secondary ion mass
✍ Bibhash R. Chakraborty; Daniel E. Lehman; Nicholas Winograd 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 193 KB 👁 2 views

Static time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been used to characterize surface contaminants on a Pt-10% Ir alloy sample prescribed for fabrication of a prototype kilogram mass standard. The identification of various oxygenated and non-oxygenated hydrocarbon adsorbates on the

Stereoregular polypropylenes studied by
✍ Xu, Keyang; Gusev, Arkady I.; Hercules, David M. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 424 KB 👁 2 views

Time-of-Ñight secondary ion mass spectrometry (ToF-SIMS) and atomic force microscopy (AFM) were utilized to characterize polypropylenes of di †erent stereoregularity (atactic, syndiotactic and isotactic) deposited on gold-or silver-coated mica surfaces. The AFM images clearly revealed distinctive su

Surface functionalization of PEEK films
✍ Henneuse-Boxus, Catherine; Poleunis, Claude; De Ro, Astrid; Adriaensen, Yasmine; 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 279 KB 👁 2 views

Using the wet chemistry method, the surface of poly(aryl ether ether ketone) (PEEK) Ðlm was selectively modiÐed to produce PEEK-OH, PEEK-COOH, PEEK-glutamine, and samples displaying, PEEK-NH 2 PEEK-SO 3 H respectively, hydroxyl, carboxyl, amino acid, amine and sulphonyl functions. All the samples we