𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Chromatographic and Immunochemical Approaches to the Analysis of the HIV Protease Inhibitor Saquinavir in Plasma

✍ Scribed by H.R. Wiltshire; B.G. Wiltshire; A.F. Clarke; E. Worth; K.J. Prior; J.F. Tjia


Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
113 KB
Volume
281
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reversephase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of ؎15%. The HPLC/UV method can be routinely applied for concentrations down to 10 -20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.


πŸ“œ SIMILAR VOLUMES


Development of a chromatographic method
✍ M. A. Campanero; M. Escolar; M. A. Arangoa; B. SΓ‘daba; J. R. Azanza πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 85 KB πŸ‘ 2 views

## Abstract A simple, sensitive and reproducible high‐performance liquid chromatographic method for detecting and quantifying saquinavir in human plasma is described. Verapamil was used as internal standard. The method employes a single liquid–liquid extraction step with __tert__‐butil methyl ether

Simultaneous determination of six HIV pr
✍ Yoshihiro Hirabayashi; Kiyoto Tsuchiya; Satoshi Kimura; Shinichi Oka πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 231 KB πŸ‘ 2 views

We report the development of a simple, economical and reliable chromatographic method for the simultaneous determination of six HIV protease inhibitors (PIs; amprenavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir), the active metabolite of nelfinavir (M8) and the non-nucleoside rever

Conformational analysis of HIV-1 proteas
✍ Murcko, Mark A.; Rao, B. Govinda; Gomperts, Roberto πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 287 KB πŸ‘ 2 views

does not contain a basic amine as do Saquinovir and JG-365, for example it should be easier to desolvate, which also assists in binding. The relationship between KNI-272, JG-365, Saquinovir, and P X proline-containing substrate also is 1

Approaches to the Immunochemical Analysi
✍ Dankwardt, A. ;Freitag, D. ;Hock, B. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 217 KB

The tendency of several pesticides to form non-extractable residues requires simple and fast screening methods. Immunochemical methods can meet this demand. They are based on selective and highly sensitive antibody binding to pesticide residues exposed on refractory organic substances (ROS). s-Triaz

Phenotypic analysis of the sensitivity o
✍ Gergely JΓ‘rmy; Martin Heinkelein; Benedikt Weissbrich; Christian Jassoy; Axel Re πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 143 KB

## Abstract Conventional phenotypic analysis of resistance of the human immunodeficiency virus (HIV) to antiviral therapy is time‐consuming and requires culture of infectious virus. Although phenotypic analyses may be desirable, rapid generation of test results and decentralized availability of the