𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Chemiluminescent assay of lipid hydroperoxides

✍ Scribed by Belghmi, Khalid ;Nicolas, Jean-Claude ;de Paulet, André Crastes


Publisher
John Wiley and Sons
Year
1988
Weight
514 KB
Volume
2
Category
Article
ISSN
0884-3996

No coin nor oath required. For personal study only.

✦ Synopsis


The addition of luminol plus a catalyst such as peroxidase or a heme prosthetic group to a solution containing a small quantity of lipid hydroperoxides results in a flash of chemiluminescence, the intensity of which is a function of the hydroperoxide concentrations. Various protocols for lipid hydroperoxide assays have been described and we have studied conditions to increase their sensitivity and specificity. Plasma lipid hydroperoxide determinations require an extraction, since compounds present in plasma interfere with light emission. Moreover, the sensitivity of the assay is by the presence of hydrogen peroxide in the medium, which causes high background values. Catalase does not act on lipid hydroperoxides and can be used to eliminate hydrogen peroxide from the reaction medium. The determination requires a blank tube in which hydroperoxides are destroyed by incubating the sample with haematin plus ascorbate. The increase in the chemiluminescence of the assay tube caused by the presence of lipid hydroperoxides is then compared to the value obtained for an internal standard.


📜 SIMILAR VOLUMES


Analysis of lipid hydroperoxides
✍ M. Carmen Dobarganes; José Velasco 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 40 KB
Detection of in vivo lipid peroxidation
✍ Kirkpatrick, Daniel T. ;Guth, Daniel J. ;Mavis, Richard D. 📂 Article 📅 1986 🏛 John Wiley and Sons 🌐 English ⚖ 609 KB

Thiobarbituric acid (TBA) assays which have been modified for detection of lipid hydroperoxides appear to be useful for demonstration of in vivo lipid peroxidation. Since these methods require heating tissue membranes with the buffered TBA, there is a possibility of interference from the detection o

Determination of lipid hydroperoxides by
✍ S. Sakura; J. Terao 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 560 KB

## Electrochenulummesnce (ECL) was used for the detectlon of the hpld hydropcronde methyl lmoleate hydroperoxlde (MLHP) at a glassy carbon electrode m acetomtnle (AN&neutral aqueous solution The cychc voltammograms of lummol and MLHP were measured to fmd the optimum apphed potential Lummol was oxl

Chemiluminescent assay of co-factors
✍ Tsuji, Akio ;Maeda, Masako ;Arakawa, Hidetoshi 📂 Article 📅 1989 🏛 John Wiley and Sons ⚖ 486 KB

Bioluminescent methods are widely used for the assay of the co-factors, NADH and ATP. Although the bioluminescent method is highly sensitive, the enzymes used are unstable and expensive. Therefore a chemiluminescent method would be valuable in clinical routine assay. We have developed a chemilumine

Evaluation of an isoluminol chemilumines
✍ Balz Frei; Yorihiro Yamamoto; Daniel Niclas; Bruce N. Ames 📂 Article 📅 1988 🏛 Elsevier Science 🌐 English ⚖ 989 KB

An assay for the separation and detection of lipid hydroperoxides and hydrogen peroxide in biological samples using HPLC and isoluminol chemiluminescence was recently described (Y. Yamamoto, M. H. Brodsky, J. C. Baker, and B. N. Ames (1987) Anal. Biochem. 160, 7-13; Y. Yamamoto and B. N. Ames (1987)