Serum theophylline analysis was attempted using stable isotope dilution mass spectrometry. Theophylline "Nlabelled in position 7 was used as internal standard. The analysis was performed at resolution 3OOO by selected ion monitoring with temperature programming. The sample was introduced in underiva
Calcium isotope analysis by mass spectrometry
β Scribed by Sergei F. Boulyga
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 555 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0277-7037
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The variations in the isotopic composition of calcium caused by fractionation in heterogeneous systems and by nuclear reactions can provide insight into numerous biological, geological, and cosmic processes, and therefore isotopic analysis finds a wide spectrum of applications in cosmoβ and geochemistry, paleoclimatic, nutritional, and biomedical studies. The measurement of calcium isotopic abundances in natural samples has challenged the analysts for more than three decades. Practically all Ca isotopes suffer from significant isobaric interferences, whereas lowβabundant isotopes can be particularly affected by neighboring major isotopes. The extent of natural variations of stable isotopes appears to be relatively limited, and highly precise techniques are required to resolve isotopic effects. Isotope fractionation during sample preparation and measurements and instrumental mass bias can significantly exceed small isotope abundance variations in samples, which have to be investigated. Not surprisingly, a TIMS procedure developed by Russell et al. (Russell et al., 1978. Geochim Cosmochim Acta 42: 1075β1090) for Ca isotope measurements was considered as revolutionary for isotopic measurements in general, and that approach is used nowadays (with small modifications) for practically all isotopic systems and with different mass spectrometric techniques. Nevertheless, despite several decades of calcium research and corresponding development of mass spectrometers, the available precision and accuracy is still not always sufficient to achieve the challenging goals. The present article discusses figures of merits of presently used analytical methods and instrumentation, and attempts to critically assess their limitations. In Sections 2 and 3, mass spectrometric methods applied to precise stable isotope analysis and to the determination of ^41^Ca are described. Section 4 contains a short summary of selected applications, and includes tracer experiments and the potential use of biological isotope fractionation in medical studies, paleoclimatic and paleoceanographic, and other terrestrial as well as extraterrestrial investigations. Β© 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:685β716, 2010
π SIMILAR VOLUMES
## Abstract For Abstract see ChemInform Abstract in Full Text.
Continuous-flow isotope ratio mass spectrometry (CF-IRMS) has been shown to minimize sample preparation and reduce the sample size requirements and time for the determination of carbon and nitrogen. An inexpensive CF inlet was developed for the determination of the 18O isotopic abundance in CO2. Ini
## Abstract The geochemistry of multiply substituted isotopologues (βclumpedβisotopeβ geochemistry) examines the abundances in natural materials of molecules, formula units or moieties that contain more than one rare isotope (e.g. ^13^C^18^O^16^O, ^18^O^18^O, ^15^N~2~, ^13^C^18^O^16^O~2~^2β^). Such
Of all the elements, hydrogen has the largest naturally occurring variations in the ratio of its stable isotopes (D/H). It is for this reason that there has been a strong desire to add hydrogen to the list of elements amenable to isotope ratio monitoring gas chromatography/mass spectrometry (irm-GC/