𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Rapid18O analysis of CO2 samples by continuous-flow isotope ratio mass spectrometry

✍ Scribed by Schoeller, D. A.; Luke, A. H.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
225 KB
Volume
32
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Continuous-flow isotope ratio mass spectrometry (CF-IRMS) has been shown to minimize sample preparation and reduce the sample size requirements and time for the determination of carbon and nitrogen. An inexpensive CF inlet was developed for the determination of the 18O isotopic abundance in CO2. Initial efforts were hampered by significant exchangeable oxygen within the inlet system, which was minimized by design changes and post-analysis mathematical correction. The system was tested for accuracy in the measurement of 18O abundance in standards and was accurate to 0.04/1000 with a precision of 0.03/1000. Additional tests were performed using urinary water for the measurement of energy expenditure by the doubly labeled water method and the results agreed to within 1% with those from traditional off-line, dual-inlet IRMS. The CF-IRMS reduced the analysis time to 2 min per sample compared with 15 min for traditional duel-inlet IRMS.


πŸ“œ SIMILAR VOLUMES


Oxygen-18 measurement by continuous flow
✍ O. BrΓ©as; C. Guillou; F. Reniero; E. Sada; F. Angerosa πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 90 KB

Stable isotopes are now increasingly used for the control of the origin or authenticity of food products. Among these techniques, the measurement of the 18 O content of organic compounds has rarely been carried out because of technical difficulties in the preparation and measurement of the samples.

Analysis of exogenous dehydroepiandroste
✍ Makoto Ueki; Masato Okano πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 96 KB πŸ‘ 1 views

A detailed procedure for the analysis of exogenous dehydroepiandrosterone (DHEA) in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been established for detecting doping with DHEA. The average d -value (parts per thousand difference of 13 C/ 12 C ratio from the

2H/1H Ratio Analysis of Flavor Compounds
✍ Ruff, Christiane ;HΓΆr, Katja ;Weckerle, Bernhard ;Schreier, Peter ;KΓΆnig, Thorst πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 41 KB πŸ‘ 1 views

Isotope ratio monitoring gas chromatography-mass spectrometry of the 2 H/ 1 H ratio by pyrolysis isotope ratio mass spectrometry (P-IRMS) was used to analyze benzaldehyde originating from various sources. Based on the d 2 H SMOW value of an authentic reference sample determined with an elemental ana

Sample vial influences on the accuracy a
✍ Stephen T. Nelson πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 59 KB πŸ‘ 2 views

Due to the small amounts of sample gas involved in continuous flow mass spectrometric analysis, care should be taken to evaluate the influence of sample containers on the carbon and oxygen isotope ratios of samples. Data indicate that Na-glass and borosilicate glass vials, equipped with butyl rubber

Determination of 15N in 15N-enriched nit
✍ Rolf Russow πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 72 KB

The 15 N tracer method is the most suitable method for studying complex N transformation processes in microbiology and biochemistry. It entails the constant determination of the 15 N abundance of the inorganic nitrogen (N) compounds nitrite and nitrate. However, 15 N analytical methods are time-cons