Continuous-flow isotope ratio mass spectrometry (CF-IRMS) has been shown to minimize sample preparation and reduce the sample size requirements and time for the determination of carbon and nitrogen. An inexpensive CF inlet was developed for the determination of the 18O isotopic abundance in CO2. Ini
Methods and limitations of ‘clumped’ CO2 isotope (Δ47) analysis by gas-source isotope ratio mass spectrometry
✍ Scribed by K. W. Huntington; J. M. Eiler; H. P. Affek; W. Guo; M. Bonifacie; L. Y. Yeung; N. Thiagarajan; B. Passey; A. Tripati; M. Daëron; R. Came
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 899 KB
- Volume
- 44
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1614
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The geochemistry of multiply substituted isotopologues (‘clumped‐isotope’ geochemistry) examines the abundances in natural materials of molecules, formula units or moieties that contain more than one rare isotope (e.g. ^13^C^18^O^16^O, ^18^O^18^O, ^15^N~2~, ^13^C^18^O^16^O~2~^2−^). Such species form the basis of carbonate clumped‐isotope thermometry and undergo distinctive fractionations during a variety of natural processes, but initial reports have provided few details of their analysis. In this study, we present detailed data and arguments regarding the theoretical and practical limits of precision, methods of standardization, instrument linearity and related issues for clumped‐isotope analysis by dual‐inlet gas‐source isotope ratio mass spectrometry (IRMS). We demonstrate long‐term stability and subtenth per mil precision in 47/44 ratios for counting systems consisting of a Faraday cup registered through a 10^12^ Ω resistor on three Thermo‐Finnigan 253 IRMS systems. Based on the analyses of heated CO~2~ gases, which have a stochastic distribution of isotopes among possible isotopologues, we document and correct for (1) isotopic exchange among analyte CO~2~ molecules and (2) subtle nonlinearity in the relationship between actual and measured 47/44 ratios. External precisions of ∼0.01‰ are routinely achieved for measurements of the mass‐47 anomaly (a measure mostly of the abundance anomaly of ^13^C‐^18^O bonds) and follow counting statistics. The present technical limit to precision intrinsic to our methods and instrumentation is ∼5 parts per million (ppm), whereas precisions of measurements of heterogeneous natural materials are more typically ∼10 ppm (both 1 s.e.). These correspond to errors in carbonate clumped‐isotope thermometry of ±1.2 °C and ±2.4 °C, respectively. Copyright © 2009 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Of all the elements, hydrogen has the largest naturally occurring variations in the ratio of its stable isotopes (D/H). It is for this reason that there has been a strong desire to add hydrogen to the list of elements amenable to isotope ratio monitoring gas chromatography/mass spectrometry (irm-GC/
A routine analysis for micro samples of plasma amino acids by a gas chromatography mass spectrometry computer system has been developed. Isotope ratio determination was used as the quantitating technique via multiple internal standards. The speed of the analysis is increased by omitting the ion exch
We present gas chromatographic/mass spectrometric and gas chromatographic/isotope ratio mass spectrometric assays of the 13C enrichment of plasma urea converted to its dimethylaminomethylene derivative. The limits of sensitivity of the two techniques are 0.2% and 0.02%, respectively. The techniques