Brain temperature and pH measured by 1H chemical shift imaging of a thulium agent
✍ Scribed by Daniel Coman; Hubert K. Trubel; Robert E. Rycyna; Fahmeed Hyder
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 539 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0952-3480
- DOI
- 10.1002/nbm.1312
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Temperature and pH are two of the most important physiological parameters and are believed to be tightly regulated because they are intricately related to energy metabolism in living organisms. Temperature and/or pH data in mammalian brain are scarce, however, mainly because of lack of precise and non‐invasive methods. At 11.7 T, we demonstrate that a thulium‐based macrocyclic complex infused through the bloodstream can be used to obtain temperature and pH maps of rat brain in vivo by ^1^H chemical shift imaging (CSI) of the sensor itself in conjunction with a multi‐parametric model that depends on several proton resonances of the sensor. Accuracies of temperature and pH determination with the thulium sensor – which has a predominantly extracellular presence – depend on stable signals during the course of the CSI experiment as well as redundancy for temperature and pH sensitivities contained within the observed signals. The thulium‐based method compared well with other methods for temperature (^1^H MRS of N‐acetylaspartate and water; copper–constantan thermocouple wire) and pH (^31^P MRS of inorganic phosphate and phosphocreatine) assessment, as established by in vitro and in vivo studies. In vitro studies in phantoms with two compartments of different pH value observed under different ambient temperature conditions generated precise temperature and pH distribution maps. In vivo studies in α‐chloralose‐anesthetized and renal‐ligated rats revealed temperature (33–34°C) and pH (7.3–7.4) distributions in the cerebral cortex that are in agreement with observations by other methods. These results show that the thulium sensor can be used to measure temperature and pH distributions in rat brain in vivo simultaneously and accurately with using biosensor imaging of redundant. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract We report acquisition of 3D image‐guided localized proton spectroscopy (^1^H‐MRS) in the human brain on a standard clinical imager. 3D coverage is achieved with a hybrid of chemical shift imaging (CSI) and transverse Hadamard spectroscopic imaging (HSI). 16 × 16 × 4 arrays of 3.5 and 1
H magnetic resonance spectroscopy was used to compare brain metabolism in 540 elderly persons, stratified by sex and age (60-90 years old). An 8 ؋ 8 ؋ 2 cm 3 supraventricular brain volume, a transverse plane parallel to the canthomeatal line, was examined by automated 1 H chemical shift imaging [poi
## Abstract Localized ^31^P NMR spectroscopy was used to evaluate the spatial heterogeneity of the metabolic response of RIF‐1 tumors to hydralazine. Volume localized ^31^P spectra were obtained from subcutaneous RIF‐1 tumors using one‐dimensional chemical‐shift imaging, before and 20 min after tre