✦ Synopsis


Recently a new fast magnetic resonance imaging strategy, SMASH, has been described, which is based on partially parallel imaging with radiofrequency coil arrays. In this paper, an internal sensitivity calibration technique for the SMASH imaging method using self-calibration signals is described. Coil sensitivity information required for SMASH imaging is obtained during the actual scan using correlations between undersampled SMASH signal data and additionally sampled calibration signals with appropriate offsets in k-space. The advantages of this sensitivity reference method are that no extra coil array sensitivity maps have to be acquired and that it provides coil sensitivity information in areas of highly non-uniform spin-density. This auto-calibrating approach can be easily implemented with only a small sacrifice of the overall time savings afforded by SMASH imaging. The results obtained from phantom imaging experiments and from cardiac studies in nine volunteers indicate that the self-calibrating approach is an effective method to increase the potential and the flexibility of rapid imaging with SMASH.


📜 SIMILAR VOLUMES


VD-AUTO-SMASH imaging
✍ Robin M. Heidemann; Mark A. Griswold; Axel Haase; Peter M. Jakob 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 341 KB

Recently a self-calibrating SMASH technique, AUTO-SMASH, was described. This technique is based on PPA with RF coil arrays using auto-calibration signals. In AUTO-SMASH, important coil sensitivity information required for successful SMASH reconstruction is obtained during the actual scan using the c

A multicoil array designed for cardiac S
✍ Griswold, M 📂 Article 📅 2000 🏛 Springer 🌐 English ⚖ 635 KB

Recently, several partially parallel acquisition (PPA) techniques have been presented which use spatial information inherent in an RF coil array to reconstruct an image from a reduced set of phase encoding steps. PPAs represent a change in paradigm for the RF coil designer since the focus for arrays

Recent advances in image reconstruction,
✍ Sodickson, D 📂 Article 📅 2002 🏛 Springer 🌐 English ⚖ 199 KB

Parallel magnetic resonance imaging (MRI) techniques use spatial information from arrays of radiofrequency (RF) detector coils to accelerate imaging. A number of parallel MRI techniques have been described in recent years, and numerous clinical applications are currently being explored. The advent o

A new procedure for calibrating the Vide
✍ B. A. Archibald; K. R. Solomon; G. R. Stephenson 📂 Article 📅 1994 🏛 Springer 🌐 English ⚖ 527 KB

Improvements in the calibration techniques used in a Video Imaging Technique for Assessing Exposure (VITAE) were examined. A series of standard curves measuring change in fluorescence with increased tracer deposition within narrow pre-exposure skin tone groupings on volunteer human subjects were dev

A parallel imaging technique using mutua
✍ Zhiqiang Li; James G. Pipe; Eric Aboussouan; John P. Karis; Donglai Huo 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 565 KB

## Abstract Split‐blade diffusion‐weighted periodically rotated overlapping parallel lines with enhanced reconstruction (DW‐PROPELLER) was proposed to address the issues associated with diffusion‐weighted echo planar imaging such as geometric distortion and difficulty in high‐resolution imaging. Th

A self-checking technique for materials
✍ U. C. Hasar 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 149 KB

## Abstract There is a need for a method for the performance evaluation of calibration‐independent measurements of dielectric materials located into a measurement cell (a coaxial or waveguide section) before starting the extraction of the complex permittivity of the sample. This is important since