## Abstract An RF multicoil array for high resolution imaging of the breast is presented. The RF multicoil is incorporated into a dedicated breast imaging apparatus that holds either breast in gentle compression during imaging. Simulations and imaging experiments demonstrate the high sensitivity an
A multicoil array designed for cardiac SMASH imaging
β Scribed by Griswold, M
- Publisher
- Springer
- Year
- 2000
- Tongue
- English
- Weight
- 635 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0968-5243
No coin nor oath required. For personal study only.
β¦ Synopsis
Recently, several partially parallel acquisition (PPA) techniques have been presented which use spatial information inherent in an RF coil array to reconstruct an image from a reduced set of phase encoding steps. PPAs represent a change in paradigm for the RF coil designer since the focus for arrays to be used with PPAs is to optimize the spatial encoding that is provided by the array. One of the first practical implementations of PPA imaging was demonstrated using the SMASH technique. In this study, we present our results from the construction of the first array designed specifically for cardiac SMASH imaging. Additional design criteria are presented for SMASH arrays that are not considered in conventional array design. Using these design criteria, a four-element array was constructed and then tested in SMASH imaging experiments in the heart. This array has been used in all of our initial cardiac and head SMASH studies with good results.
π SIMILAR VOLUMES
In this study we present a method to simulate complex phased array coil designs for cardiac imaging. It is based on the combination of numerically calculated B 1 field vectors for each coil of the array and a noise resistance data set, which is acquired only once with a set of test coils. This techn
Recently a new fast magnetic resonance imaging strategy, SMASH, has been described, which is based on partially parallel imaging with radiofrequency coil arrays. In this paper, an internal sensitivity calibration technique for the SMASH imaging method using self-calibration signals is described. Coi
## Abstract A lightweight 32βelement MRI receiverβcoil array was designed and built for cardiac imaging. It comprises an anterior array of 21 copper rings (75 mm diameter) and a posterior array of 11 rings (107 mm diameter) that are arranged in hexagonal lattices so as to decouple nearest neighbors
We prospectively compared standard resolution and high resolution breath-hold T1-and T2-weighted images of the upper abdomen with use of a body phased-array multicoil in 30 patients. The image quality of high resolution T1-weighted FLASH sequence was equal to that of standard resolution sequence, wh