✦ Synopsis


In this study we present a method to simulate complex phased array coil designs for cardiac imaging. It is based on the combination of numerically calculated B 1 field vectors for each coil of the array and a noise resistance data set, which is acquired only once with a set of test coils. This technique allowed fast assessment of the SNR performance of arbitrary geometries of single coils to be used as building blocks in complex array configurations. In addition, since clinical scanners usually provide only four receiver channels, we used this method to investigate the use of hardware combiners for different array configurations, consisting of up to eight coils. Simulated array geometries resulted in up to :30% gain in SNR for deep cardiac structures, compared to a conventional linear four coil array. This was confirmed by phantom experiments with implemented coils.


📜 SIMILAR VOLUMES


Three-element phased-array coil for imag
✍ Kishore V. Mogatadakala; James A. Bankson; Ponnada A. Narayana 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 526 KB

## Abstract To overcome some of the limitations of an implantable coil, including its invasive nature and limited spatial coverage, a three‐element phased‐array coil is described for high‐resolution magnetic resonance imaging (MRI) of rat spinal cord. This coil allows imaging both thoracic and cerv

Geometrical optimization of a phased arr
✍ A. Liffers; H.H. Quick; C.U. Herborn; H. Ermert; M.E. Ladd 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 363 KB

## Abstract The geometry of an RF phased‐array receiving coil for high‐resolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signal‐to‐noise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging si

Design and evaluation of a 32-channel ph
✍ Florian M. Meise; Julien Rivoire; Maxim Terekhov; Graham C. Wiggins; Boris Keil; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 453 KB

## Abstract Imaging with hyperpolarized 3‐helium is becoming an increasingly important technique for MRI diagnostics of the lung but is hampered by long breath holds (>20 sec), which are not always applicable in patients with severe lung disease like chronic obstructive pulmonary disease (COPD) or

Focused, eight-element transceive phased
✍ Bing Keong Li; Feng Liu; Stuart Crozier 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 720 KB

## Abstract A new transceive system for chest imaging for MRI applications is presented. A focused, eight‐element transceive torso phased array coil is designed to investigate transmitting a focused radiofrequency field deep within the torso and to enhance signal homogeneity in the heart region. Th