## Abstract An inductively coupled implanted coil was designed for high‐resolution magnetic resonance (MR) studies of rat spinal cord (SC) in vivo at 7 T. The practical issues involved in implementation of the coil at high fields are discussed, and the adjustment of various parameters for optimizin
Three-element phased-array coil for imaging of rat spinal cord at 7T
✍ Scribed by Kishore V. Mogatadakala; James A. Bankson; Ponnada A. Narayana
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 526 KB
- Volume
- 60
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
To overcome some of the limitations of an implantable coil, including its invasive nature and limited spatial coverage, a three‐element phased‐array coil is described for high‐resolution magnetic resonance imaging (MRI) of rat spinal cord. This coil allows imaging both thoracic and cervical segments of rat spinal cord. In the current design, coupling between the nearest neighbors was minimized by overlapping the coil elements. A simple capacitive network was used for decoupling the next neighbor elements. The dimensions of individual coils in the array were determined based on the signal‐to‐noise ratio (SNR) measurements performed on a phantom with three different surface coils. SNR measurements on a phantom demonstrated higher SNR for the phased array coil relative to two different volume coils. In vivo images acquired on rat spinal cord with our coil demonstrated excellent gray and white matter contrast. To evaluate the performance of the phased array coil under parallel imaging, __g‐__factor maps were obtained for acceleration factors of 2 and 3. These simulations indicate that parallel imaging with an acceleration factor of 2 would be possible without significant image reconstruction–related noise amplifications. Magn Reson Med 60:1498–1505, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract A new transceive system for chest imaging for MRI applications is presented. A focused, eight‐element transceive torso phased array coil is designed to investigate transmitting a focused radiofrequency field deep within the torso and to enhance signal homogeneity in the heart region. Th
## Abstract Regional values of fractional anisotropy (FA) and mean diffusivity (__D__~av~) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) read
## Abstract ## Purpose: To compare a new birdcage‐transmit, 28‐channel receive array (28‐Ch) coil and a quadrature volume coil for 7T morphologic MRI and T2 mapping of knee cartilage. ## Materials and Methods: The right knees of 10 healthy subjects were imaged on a 7T whole body magnetic resonan