๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI

โœ Scribed by Sodickson, D


Publisher
Springer
Year
2002
Tongue
English
Weight
199 KB
Volume
13
Category
Article
ISSN
0968-5243

No coin nor oath required. For personal study only.

โœฆ Synopsis


Parallel magnetic resonance imaging (MRI) techniques use spatial information from arrays of radiofrequency (RF) detector coils to accelerate imaging. A number of parallel MRI techniques have been described in recent years, and numerous clinical applications are currently being explored. The advent of practical parallel imaging presents various challenges for image reconstruction and RF system design. Recent advances in tailored SiMultaneous Acquisition of Spatial Harmonics (SMASH) image reconstructions are summarized. These advances enable robust SMASH imaging in arbitrary image planes with a wide range of coil array geometries. A generalized formalism is described which may be used to understand the relations between SMASH and SENSE, to derive typical implementations of each as special cases, and to form hybrid techniques combining some of the advantages of both. Accurate knowledge of coil sensitivities is crucial for parallel MRI, and errors in calibration represent one of the most common and the most pernicious sources of error in parallel image reconstructions. As one example, motion of the patient and/or the coil array between the sensitivity reference scan and the accelerated acquisition can lead to calibration errors and reconstruction artifacts. Self-calibrating parallel MRI approaches that address this problem by eliminating the need for external sensitivity references are reviewed. The ultimate achievable signal-to-noise ratio (SNR) for parallel MRI studies is closely tied to the geometry and sensitivity patterns of the coil arrays used for spatial encoding. Several parallel imaging array designs that depart from the traditional model of overlapped adjacent loop elements are described.


๐Ÿ“œ SIMILAR VOLUMES


Sensitivity profiles from an array of co
โœ Walid E. Kyriakos; Lawrence P. Panych; Daniel F. Kacher; Carl-Fredrick Westin; S ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 441 KB

A new parallel imaging technique was implemented which can result in reduced image acquisition times in MRI. MR data is acquired in parallel using an array of receiver coils and then reconstructed simultaneously with multiple processors. The method requires the initial estimation of the 2D sensitivi