𝔖 Bobbio Scriptorium
✦   LIBER   ✦

VD-AUTO-SMASH imaging

✍ Scribed by Robin M. Heidemann; Mark A. Griswold; Axel Haase; Peter M. Jakob


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
341 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Recently a self-calibrating SMASH technique, AUTO-SMASH, was described. This technique is based on PPA with RF coil arrays using auto-calibration signals. In AUTO-SMASH, important coil sensitivity information required for successful SMASH reconstruction is obtained during the actual scan using the correlation between undersampled SMASH signal data and additionally sampled calibration signals with appropriate offsets in k-space. However, AUTO-SMASH is susceptible to noise in the acquired data and to imperfect spatial harmonic generation in the underlying coil array. In this work, a new modified type of internal sensitivity calibration, VD-AUTO-SMASH, is proposed. This method uses a VD k-space sampling approach and shows the ability to improve the image quality without significantly increasing the total scan time. This new k-space adapted calibration approach is based on a k-space-dependent density function. In this scheme, fully sampled low-spatial frequency data are acquired up to a given cutoff-spatial frequency. Above this frequency, only sparse SMASH-type sampling is performed. On top of the VD approach, advanced fitting routines, which allow an improved extraction of coil-weighting factors in the presence of noise, are proposed. It is shown in simulations and in vivo cardiac images that the VD approach significantly increases the potential and flexibility of rapid imaging with AUTO-SMASH.


πŸ“œ SIMILAR VOLUMES


AUTO-SMASH: A self-calibrating technique
✍ Jakob, P πŸ“‚ Article πŸ“… 1998 πŸ› Springer 🌐 English βš– 509 KB

Recently a new fast magnetic resonance imaging strategy, SMASH, has been described, which is based on partially parallel imaging with radiofrequency coil arrays. In this paper, an internal sensitivity calibration technique for the SMASH imaging method using self-calibration signals is described. Coi

Generalized SMASH imaging
✍ Mark Bydder; David J. Larkman; Joseph V. Hajnal πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 890 KB

## Abstract A generalized parallel imaging method has been developed that uses coil profiles to generate missing __k__‐space lines. The proposed method is an extension of SMASH, which uses linear combinations of coil sensitivity profiles to synthesize spatial harmonics. In the generalized SMASH app

Auto-calibrated parallel spiral imaging
✍ Keith Heberlein; and Xiaoping Hu πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 940 KB

## Abstract This work describes an auto‐calibrated method for parallel imaging with spiral trajectory. The method is a __k__‐space approach where an interpolation kernel, accounting for coil sensitivity factors, is derived from experimental data and used to interpolate the reduced data set in paral

Coil-by-coil image reconstruction with S
✍ Charles A. McKenzie; Michael A. Ohliger; Ernest N. Yeh; Mark D. Price; Daniel K. πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 237 KB

## Abstract The SiMultaneous Acquisition of Spatial Harmonics (SMASH) technique uses linear combinations of undersampled datasets from the component coils of an RF coil array to reconstruct fully sampled composite datasets in reduced imaging times. In previously reported implementations, SMASH reco

A multicoil array designed for cardiac S
✍ Griswold, M πŸ“‚ Article πŸ“… 2000 πŸ› Springer 🌐 English βš– 635 KB

Recently, several partially parallel acquisition (PPA) techniques have been presented which use spatial information inherent in an RF coil array to reconstruct an image from a reduced set of phase encoding steps. PPAs represent a change in paradigm for the RF coil designer since the focus for arrays