Amperometric detector with a manganin electrode for microcolumn liquid chromatography
✍ Scribed by K Šlais
- Publisher
- Elsevier Science
- Year
- 1988
- Tongue
- English
- Weight
- 661 KB
- Volume
- 442
- Category
- Article
- ISSN
- 1873-3778
No coin nor oath required. For personal study only.
✦ Synopsis
The response of manganin and copper microelectrodes in amino acid solution was evaluated by using slow-scanning voltammetry. Enhancement of the complexation rate of the manganin electrode in relation to the copper electrode is explained on the basis of the properties of the electrode surface. Based on voltammetric measurements, manganin is suggested as a working electrode material for the confined wall-jet microflow-cell of an amperometric detector. The detector performance was tested under the conditions of reversed-phase microcolumn liquid chromatography using selected amino acids and dipeptides as the solutes. Employing flow-rates up to 1 &s, an increase in response corresponding to the l/3 power of the flow-rate was found, which indicates that a diffusion-limited electrode reaction occurs. The minimum detectable concentrations of the amino acids and some dipeptides in the ranges 0.04-0.08 and 0.1-0.25 ~44, respectively, appear promising for application of this detector to trace analysis.
📜 SIMILAR VOLUMES
Chemically modified electrodes (CMEs) prepared by the dispersion of metal oxide particles on a glassy carbon (GC) substrate greatly enhance the voltammetric response and amperometric detection of local anesthetics following liquid chromatography (LC). The enhancement is more pronounced with the GC e
A miniaturized evaporative light scattering detector ELSD compatible Ž . with packed microcolumn high-performance liquid chromatography HPLC has been developed. In such a detector, it is particularly important that an efficient nebulization of the column effluent is achieved. Therefore, the geometry
A nickel-chromium alloy electrode was applied as an electrochemical detector for the analysis of carbohydrates by high performance anion-exchange liquid chromatography. This alloy electrode exhibited excellent sensitivity, reproducibility and stability. The carbohydrates are oxidatively detected by
A method for the determination of N-acetylcysteine, cysteine and their disulfides in urine is described. The thiols and disulfides are separated by reversed-phase ion-pair chromatography with octyl sodium sulfate as the ion-pairing reagent and detected with a dual-electrode amperometric detector usi