A variation of transmission electron microscope sample preparation for VLSI analysis

✍ Scribed by Madden, Michael C. ;Crafard, Penny


Publisher
Wiley (John Wiley & Sons)
Year
1989
Tongue
English
Weight
593 KB
Volume
11
Category
Article
ISSN
0741-0581

No coin nor oath required. For personal study only.

✦ Synopsis


Sample preparation for VLSI analysis is often slow due to long ion milling time and because the location of the thin area of the sample is difficult to control. By modifying the standard techniques used with a VCR Group (and perhaps other) mechanical dimpler, the ion milling time can be reduced to less than 30 min. and the location on the thinned area reasonably controlled. These modifications involve the use of a radiused edge on the dimpling tool, a rubber O-ring on the polishing tool, and not rotating the sample platen during polishing. The modifications to the dimpling and polishing tools allow more control of the geometry of the dimple, while not rotating the sample platen allows a thinner sample to be produced and permits the use of the sample translation micrometers to shift the location of the thinned area during polishing. The quality of samples produced using this modified procedure is equivalent to that obtained with the more standard methods.


πŸ“œ SIMILAR VOLUMES


Sample preparation technique for cross-s
✍ Yu-Pei Chen; Jason D. Reed; Sean S. O'Keefe; William J. Schaff; Lester F. Eastma πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 363 KB πŸ‘ 1 views

A novel cross-sectional sample preparation technique for quantum wire (QWR) structures is described. By coating a thin layer of Au with a designed pattern on the sample as a marker to indicate the position of the wire pattern, the location of the thinned area can be controlled precisely. An example

A transmission electron microscope (TEM)
✍ J. P. McCaffrey; J.-M. Baribeau πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 811 KB

A calibration sample for transmission electron microscopy (TEM) has been developed that performs the three major instrument calibrations for a transmission electron microscope: the image magnification calibration for measurements of images, the camera constant calibration for indexing diffraction pa

Dynamic focussing for recording images f
✍ Zemlin, F. πŸ“‚ Article πŸ“… 1989 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 580 KB

For three-dimensional electron microscopical structure research the specimen must be imaged in a tilted position. Specimen tilt is also often needed to achieve an optimal molecular packing orientation. The tilt with respect to the optical axis causes a defocus gradient alongside the imaged area and