A screening method based on liquid chromatography/electrospray tandem mass spectrometry was developed in order to control the illegal use of corticosteroids as growth promoters in cattle. The objective was the detection of low residue levels of corticosteroids or metabolites in biological matrices.
A Simple High Performance Liquid Chromatography/Ionspray Tandem Mass Spectrometry Method for the Direct Determination of Paraquat and Diquat in Water
β Scribed by Julie C. Marr; James B. King
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 106 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
A method has been developed for the direct determination of paraquat and diquat in water samples. No sample preparation was required and analysis was done using high performance liquid chromatography coupled with ionspray tandem mass spectrometry. Heptafluorobutyric acid was used as the ion-pair agent. Further improvements in this method included the incorporation of an internal standard (caffeine). Using this method, detection limits of 5 and 1 Β΅g/L were obtained for paraquat and diquat respectively. Recoveries were consistently > 90% with relative standard deviations of < 10% over the concentration range 5-100 Β΅g/L. To our knowledge, this method is the first application of ionspray tandem mass spectrometry, and the first to use heptafluorobutyric acid as an ion-pair reagent, for the analysis of paraquat and diquat.
π SIMILAR VOLUMES
A sensitive, specific and accurate high performance liquid chromatography/ionspray-tandem mass spectrometry procedure (HPLC/MS/MS) has been developed to quantify cyclophosphamide in human urine from hospital personnel involved in drug preparation and administration of antineoplastic alkylating agent
The performance of electrospray ionization and atmospheric pressure chemical ionisation (APCI) for the analysis of carotenoids was investigated. On our instrument, APCI produced spectra which were readily interpreted, and the positive-ion mode proved applicable to all of the compounds. The separatio
Four sensitive, specific and accurate methods, based on high-performance liquid chromatography (HPLC) with positive ion electrospray tandem mass spectrometry (MS/MS) coupled with liquid-liquid extraction (LLE), have been developed and validated for the low-picogram determination of two drug candidat
A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T
This work describes real examples of classes of drugs (drug candidates) whose quantitative determination in biological matrices by high performance liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) may be hampered by interferences from drug-related biotransformation product