Because of the potential in-source conversion between a lactone and the corresponding hydroxy acid, it has been recognized that a liquid chromatography/tandem mass spectrometric (LC/MS/MS) method developed for quantitation of a lactone drug in the presence of its hydroxy acid metabolite (or vice ver
The need for adequate chromatographic separation in the quantitative determination of drugs in biological samples by high performance liquid chromatography with tandem mass spectrometry
โ Scribed by Mohammed Jemal; Yuan-Qing Xia
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 128 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
This work describes real examples of classes of drugs (drug candidates) whose quantitative determination in biological matrices by high performance liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) may be hampered by interferences from drug-related biotransformation products (or prodrugs), unless the chromatographic conditions used achieve the separation of the drug from drug-related compounds. The classes of drugs investigated include: (a) a lactone drug, with the open-ring acid as the potential biotransformation product; (b) a phenolic drug and its prodrug; (c) an E-isomer methyloxime drug, with its Z-isomer as the potential biotransformation product; (d) a carboxylic acid drug, with its acylglucuronide as the potential biotransformation product; and (e) a thiol drug, with its disulfide as the potential biotransformation product. For each pair of a drug and the associated compound (except for the isomeric pair), the full-scan electrospray single mass spectrum of the associated compound gave an insource collisionally induced dissociation (CID) generated fragment ion identical to the parent ion of the drug. Thus, the associated compound, if present in the biological sample, would interfere with the quantitative determination of the drug by LC/MS/MS using the selected reaction monitoring (SRM) transition of the parent ion of the drug, unless the LC conditions utilized achieve clearcut separation of the drug from the associated compound. Thus, LC/MS/MS bioanalytical methods with very short retention times, where there are minimal chromatographic separations, should be used only for biological samples which are known to not contain analyte-related compounds that can undergo the SRM transition used for the drug determination.
๐ SIMILAR VOLUMES
A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp
A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced
A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T
There is a continuing need for increased throughput in the evaluation of new drug entities in terms of their pharmacokinetic (PK) parameters. This report describes an alternative procedure for increasing the throughput of plasma samples assayed in one overnight analysis: the use of parallel high per
Four sensitive, specific and accurate methods, based on high-performance liquid chromatography (HPLC) with positive ion electrospray tandem mass spectrometry (MS/MS) coupled with liquid-liquid extraction (LLE), have been developed and validated for the low-picogram determination of two drug candidat