A new standard reference material for column evaluation in reversed-phase liquid chromatography
β Scribed by Lane C. Sander; Stephen A. Wise
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 500 KB
- Volume
- 26
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
A new Standard Reference Material (SRM) for use in characterizing general aspects of liquid chromatographic column performance is described. SRM 870 Column Performance Test Mixture for Liquid Chromatography contains five components: uracil, toluene, ethylbenzene, quinizarin, and amitriptyline, and is intended to provide indications of column void volume, hydrophobicity, methylene selectivity, activity toward organic bases, and activity toward metal chelators. The test is performed under neutral, buffered conditions. The measurement of retention and peak asymmetry factors for the components facilitates column classification. It is anticipated that this material will be useful (1) in column selection during method development, (2) as a control material to monitor column performance over time, and (3) in quality control in column manufacturing.
π SIMILAR VOLUMES
## Abstract A new technique for coupling reversedβphase liquid chromatography (RPLC) with gas chromatography is described. A fraction eluting from an RPLC column is trapped on a short column packed with polymeric adsorbent. After the mobile phase has been displaced with water, the analytes are deso
## Abstract The performance of etched borosilicate capillary columns with a bonded octadecyl stationary phase has been examined. Plate heights for three test compounds in columns with inner diameters between 6.5 and 14.6 ΞΌm were measured as a function of mobile phase velocity. The reduced plate hei
## Abstract The robustness of the popular βTanakaβ LC column characterization protocol has been evaluated by the statistical tools of reduced factorial design, multiple linear regression and principal component analysis. These have shown that in order to obtain reliable and reproducible results, it