𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A new linear ion trap time-of-flight system with tandem mass spectrometry capabilities

✍ Scribed by J. M. Campbell; B. A. Collings; D. J. Douglas


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
615 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A new hybrid linear ion trap time-of-flight mass spectrometer has been constructed and the first results for tandem-in-time MS/MS in a 2-dimensional Paul trap are presented. The instrument consists of an electrospray ionization source and two radio frequency (RF) only quadrupoles operating at a pressure of 7 mTorr N 2 which are coupled orthogonally to a linear TOFMS. Ions are trapped in an RF-only quadrupole through the application of timed stopping potentials on the entrance and exit apertures. Through the coupling of an auxiliary waveform generator on one pair of the ion trap rods a small dipolar excitation voltage is superimposed on the quadrupolar electric field. This voltage is used for precursor isolation via broadband excitation and collision induced dissociation through mass selective resonant excitation. Instrumental performance and choice of operating parameters are demonstrated by recording fragment spectra for 3 ions of renin substrate and 1 ions of reserpine. TOFMS mass resolution (m/Dm) FWHM is as high as 740 at m/z = 609. Fragmentation efficiency is greater than 50% and excitation mass resolution is 60-75.


πŸ“œ SIMILAR VOLUMES


Procedures for Tandem Mass Spectrometry
✍ Mark G. Qian; David M. Lubman πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 835 KB

In this work, we demonstrate tandem mass spectrometry on an ion trap storage-reflectron time-of-fight mass spectrometer (IT/reTOFMS). Ion isolation and activation were achieved by resonant excitation using multi-and single-frequency waveforms generated from an analog circuit. Product-ion spectra of

Investigation of the quantitative capabi
✍ Randy W. Purves; Wojciech Gabryelski; Liang Li πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 166 KB πŸ‘ 3 views

The quantitative analysis of pharmaceutical or environmental compounds represents an important application area of electrospray ionization (ESI) mass spectrometry (MS). Typically, these analyses are carried out using quadrupole mass analyzers. Recently, several other mass spectrometric configuration

A New Focused Ion Beam Optical System fo
✍ H. Shichi; S. Osabe; K. Kanehori πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 157 KB πŸ‘ 2 views

A new focused ion beam optical system that uses a liquid metal ion source was designed for a new secondary ion time-of-flight mass spectrometry instrument. This optical system consists mainly of two electrostatic lenses. The axial performance of the system was calculated to decide the design values

A quadrupole ion trap/time-of-flight mas
✍ Doroshenko, Vladimir M.; Cotter, Robert J. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 470 KB πŸ‘ 2 views

A matrix-assisted laser desorption/ionization-quadrupole ion trap/reΓ‘ectron time-of-Γ‘ight (MALDI-QIT/reTOF) mass spectrometer design and its operation in both normal and tandem mass spectrometric modes are described. A parabolic reΓ‘ectron was found to be capable of providing mass resolution of 5000

Development of a capillary high-performa
✍ Ling He; Jing-Tao Wu; Steve Parus; David M. Lubman πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 207 KB πŸ‘ 3 views

In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourie

Optimization of a quadrupole ion storage
✍ Beni B. Dangi; Kent M. Ervin πŸ“‚ Article πŸ“… 2012 πŸ› John Wiley and Sons 🌐 English βš– 386 KB

Designs of a quadrupole ion trap (QIT) as a source for time‐of‐flight (TOF) mass spectrometry are evaluated for mass resolution, ion trapping, and laser activation of trapped ions. Comparisons are made with the standard hyperbolic electrode ion trap geometry for TOF mass analysis in both linear and