A molecule ion reactor (MIR), i.e. a gas filled radio-frequency only quadrupole with a longitudinal electrical field (RFQLEF), is used as an atmospheric pressure ionization interface for an orthogonal time-of-flight mass spectrometer (O-TOFMS). A new phenomenon of selective ion 'heating' in a MIR ne
A New Focused Ion Beam Optical System for a Time-of-flight-Secondary Ion Mass Spectrometry Instrument
โ Scribed by H. Shichi; S. Osabe; K. Kanehori
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 157 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
A new focused ion beam optical system that uses a liquid metal ion source was designed for a new secondary ion time-of-flight mass spectrometry instrument. This optical system consists mainly of two electrostatic lenses. The axial performance of the system was calculated to decide the design values to be adopted. A calculated minimum beam diameter of 10 nm and a mean current of 4 pA, which are sufficient for highly sensitive microarea element analysis, were obtained under the conditions where the acceleration voltage was 40 kV, the working distance between the einzel objective lens and a sample was 6 mm, and the thickness of the objective lens was 8 mm.
๐ SIMILAR VOLUMES
CsI) n Cs + projectiles, n = 0-3, were used to bombard a NaBF 4 (sodium tetrafluoroborate) target at the limit of single ion impacts. The relative yields of ions sputtered from the target were measured and are compared as a function of the number of atoms in the primary ion. When normalized to the m
In the rapidly growing รeld of combinatorial chemistry, the Multipin approach has been used for rapid and efficient multiple parallel syntheses of organic compounds. This strategy is particularly well adapted for the optimization of reaction conditions prior to chemical library syntheses, for the pr
The use of time-of-flight secondary ion mass spectrometry (Tof-SIMS) for the step-by-step control of a peptide synthesis on a solid support is illustrated. The positive secondary ions, issuing from energetic fragmentation, are characteristic of the terminal groups of the step under investigation. Th
In this study, time-of-flight secondary ion mass spectrometry was used to distinguish between blood of normal infants and that of individuals with Smith-Lemli-Opitz (SLO) syndrome. SLO syndrome results in an abnormally low concentration of blood cholesterol and an elevated concentration of 7dehydroc
In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourie