๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

00/02916 Performance enhancement of some alternatives to R-502


Book ID
108397812
Publisher
Elsevier Science
Year
2000
Weight
209 KB
Volume
41
Category
Article
ISSN
0140-6701

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Performance enhancement of some alternat
โœ Samuel M. Sami; Daniel E. Desjardins ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 133 KB

The results of an experimental study on the behaviour of some new alternatives to R-502 using heated suction accumulator are presented. The experimental set up was composed of a fully instrumented air}source heat pump with a capacity of 12 000 BTUH and equipped with a heated suction accumulator. Th

00/02915 Performance comparative study o
๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› Elsevier Science โš– 209 KB

of air-conditioning, there is a report on how performance differs according to outdoor summer thermohygrometric design conditions, such as those indicated by UN1 10339, by ASHRAE and by the processing of TRY data. Finally, this paper discusses the optimal choice of design conditions according to the

Performance of some zeotropic mixtures a
โœ G. Venkatarathnam; S. Srinivasa Murthy ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 158 KB

Many zeotropic refrigerant mixtures are being proposed as alternatives to CFCs and HFCFs refrigerants that are being phased out. The main advantage in the use of zeotropic mixtures is the possibility of reduction in entropy generation in the condenser and evaporator by matching the glides of refrige

Performance comparative study of new alt
โœ Samuel M. Sami; Daniel E. Desjardins ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 123 KB ๐Ÿ‘ 2 views

In this paper the test results of a performance evaluation of new alternatives; R-407B, R-507, R-408A and R-404A as substitutes to CFC-502 are presented. The test results were obtained using an air-source heat pump with enhanced surface tubing under standard ARI conditions. The data demonstrated th

Boiling characteristics of alternatives
โœ Samuel M. Sami; Daniel E. Desjardins ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 140 KB ๐Ÿ‘ 2 views

In this paper, an experimental study on the heat transfer characteristics of two-phase #ow boiling of alternative zeotropic refrigerant mixtures to R-502, on air/refrigerant horizontal enhanced surface tubing is presented. The new alternatives considered in this study are: R-507, R-404A, R-407B, and