## Abstract The __in situ__ preparation of monolithic capillary columns comprising copolymers of butyl methacrylate with ethylene dimethacrylate, diethylene glycol dimethacrylate, triethylene glycol dimethacrylate, and pentaerythritol tetraacrylate using thermal polymerization within 250 μm ID capi
Versatility of polymethacrylate monoliths for chromatographic purification of biomolecules
✍ Scribed by Michael W. H. Roberts; Clarence M. Ongkudon; Gareth M. Forde; Michael K. Danquah
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 773 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Polymethacrylate monoliths, specifically poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) or poly(GMA‐__co‐__EDMA) monoliths, are a new generation of chromatographic supports and are significantly different from conventional particle‐based adsorbents, membranes, and other monolithic supports for biomolecule purification. Similar to other monoliths, polymethacrylate monoliths possess large pores which allow convective flow of mobile phase and result in high flow rates at reduced pressure drop, unlike particulate supports. The simplicity of the adsorbent synthesis, pH resistance, and the ease and flexibility of tailoring their pore size to that of the target biomolecule are the key properties which differentiate polymethacrylate monoliths from other monoliths. Polymethacrylate monoliths are endowed with reactive epoxy groups for easy functionalization (with anion‐exchange, hydrophobic, and affinity ligands) and high ligand retention. In this review, the structure and performance of polymethacrylate monoliths for chromatographic purification of biomolecules are evaluated and compared to those of other supports. The development and use of polymethacrylate monoliths for research applications have grown rapidly in recent times and have enabled the achievement of high through‐put biomolecule purification on semi‐preparative and preparative scales.
📜 SIMILAR VOLUMES
## Abstract The suitability of methacrylate based anion exchange monolithic supports for the separation and purification of plasmid and genomic DNA has been explored. The effect of the size of the channels, ionic strength of the solution, and ligand density on the dynamic binding capacity has been
## Abstract Organic polymer monolithic capillary columns were prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of po