𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of monolithic silica and polymethacrylate capillary columns for LC

✍ Scribed by Dana Moravcová; Pavel Jandera; Jiří Urban; Josef Planeta


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
855 KB
Volume
27
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Organic polymer monolithic capillary columns were prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of porogenic solvent mixtures and different concentration ratios of monomers and 1‐propanol, 1,4‐butanediol, and water. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica‐based particulate and monolithic capillary and analytical HPLC columns. The tests included the determination of H‐u curves, column permeabilities, pore distribution by inversed‐SEC measurements, methylene and polar selectivities, and polar interactions with naphthalenesulphonic acid test samples. Organic polymer monolithic capillary columns show similar retention behaviour to chemically bonded alkyl silica columns for compounds with different polarities characterized by interaction indices, I~x~, but have lower methylene selectivities and do not show polar interactions with sulphonic acids. The commercial capillary and analytical silica gel‐based monolithic columns showed similar selectivities and provided symmetrical peaks, indicating no significant surface heterogeneities. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra‐column contributions. With 0.3 mm ID capillary columns, corrections for extra‐column volume contributions are sufficient, but to obtain true information on the efficiency of 0.1 mm ID capillary columns, the experimental bandwidths should be corrected for extra‐column contributions to peak broadening.


📜 SIMILAR VOLUMES


Silica-based and organic monolithic capi
✍ Johan Rozenbrand; Wouter P. van Bennekom 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 337 KB

## Abstract The use of monolithic liquid chromatography (LC) columns for proteomics, covering the scientific literature from 2004 to the beginning of 2011, is reviewed. Attention is paid to recent developments in column technology and materials, focusing on silica‐based and organic (polystyrene and

Optimization of the porous structure and
✍ Sebastiaan Eeltink; Laurent Geiser; Frantisek Svec; Jean M. J. Fréchet 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 771 KB

## Abstract The porous structure as well as the polarity of methacrylate ester‐based monolithic stationary phases has been optimized to achieve the separation of various peptides originating from enzymatic digestion. The porous structure, determined by the size of both pores and microglobules, was

On the stability of micro-LC columns (pa
✍ De Weerdt, M. ;Dewaele, C. ;Verzele, M. 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 316 KB

The life expectancy and resistance to flow, pressure shocks, solvent gradients, and bending of packed fused silica capillary columns (Micro-LC) are discussed. ## 2 Instrumentation Chromatographic measurements were carried out on a Varian 5020 (Varian Associates, Walnut Creek, CA, USA) and on a Per