High-resolution Infrared Laser Desorption/Ionization and Matrix-assisted
Utilizing Time-lag Focusing Matrix-assisted Laser Desorption/Ionization Mass Spectrometry for the End Group Analysis of Synthetic Polymers
β Scribed by Anthony T. Jackson; Hilary T. Yates; Chris I. Lindsay; Yves Didier; John A. Segal; James H. Scrivens; Glenn Critchley; Jeff Brown
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 236 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
Time-lag focusing matrix-assisted laser desorption/ionization mass spectrometry has been employed to analyse synthetic polymers with average molecular weights between approximately 3500 and 12 500 Da. Spectra are shown that demonstrate the improvement in resolution and sensitivity when time-lag focusing is used instead of prompt extraction techniques. A resolution of almost 9000 (full width at half maximum) was obtained, in the reflectron mode of operation, for a poly(methyl methacrylate) (PMMA) sample with a relatively narrow range of molecular weights. The data for PMMA polymers of industrial relevance easily enable the differentiation of many end groups as a consequence of the improved signal-to-noise ratio and the good mass accuracy when time-lag focusing is employed.
π SIMILAR VOLUMES
Synthetic polymers having a polydispersity greater than 1.1 cannot be reliably characterized by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry alone. This complication has been overcome by off-line coupling of size-exclusion chromatography (SEC) with MALDI. Data
## Matrix -assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to demonstrate the reproducibility of bacterial spectra collected on different days. The reproducibility of analysis by MALDI-MS of intact Escherichia coli and Bacillus atrophaeus is presented a
RNase H is an endonuclease which cleaves RNA at points of hybridization with DNA. However, certain ambiguities exist in terms of its speciΓcity and location of cleavage along the RNA strand. The analysis of RNase H reaction products of an oligoribonucleotide hairpin by matrix-assisted laser desorpti
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate.
An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed