Use of submicroliter-volume samples for extending the dynamic range of flow-injection flame atomic absorption spectrometry

✍ Scribed by I.López García; P. Viñas; N. Campillo; M.Hernández Córdoba


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
938 KB
Volume
308
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Three computer-controlled flow-injection manifolds for extending the determination range of flame atomic absorption spectrometry are discussed. All the manifolds are based on the metering of very small sample volumes into a slowly moving carrier, the flow rate of which is gradually modified after completion of the injection. The systems use a conventional peristaltic pump equipped with small bore pump tubes and a channel to compensate for the difference between the flow delivered by the pump and the nebulizer uptake rate. The main difficulty which must be overcome is the pulsation caused by the rollers of the pump. The first manifold uses two or more metering steps, separated by an appropriate time interval and performed on the sample which is injected into the carrier propelled by the pump running at a low speed. The reproducibility is poor because the pump pulsations are periodic but highly asymmetric. The second system uses a single metering stage into the compensation channel performed while the pump is delivering the carrier at a flow rate close to the nebulizer uptake rate. Relative standard deviations ranging + 0.6-2% are obtained but the maximum dilution degree attainable is about 2000. The third manifold is similar to the first, but a single metering stage is performed, the position of the rollers at the beginning of the metering step being controlled by means of a simple optical device. In this way, volumes as low as 0.02 ~1 can be metered into the system and dilution degrees of about 20,000 can be obtained. By choosing appropriate pump rates and metering times, a wide range of dilution degrees can be obtained. Sampling frequencies are in the 60-80 samples h-' range. Calibration can be performed by using peak height or integrated absorbance. Repeatability of the integrated absorbance measurements is in the + 1.1-3.3% range.


📜 SIMILAR VOLUMES


Determination of cadmium, copper and lea
✍ Renli Ma; Willy Van Mol; Freddy Adams 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 998 KB

A flow injection on-line sorbent extraction system was studied in conjunction with flame atomic absorption spectrometry to determine cadmium, copper and lead in digest solutions of solid environmental samples using octadecyl functional groups (C,,) bonded silica gel as sorbent with diethylammonium-Z

Determination of copper in water and ric
✍ Hengwu Chen; Shukun Xu; Zhaolun Fang 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 756 KB

A flow-injection on-I& adsorption precontentration flame atomic absorption spectrometric system for the detenninatian of copper was developed. The copper d~eth~ldith~~arba~ate chefate was adsorbed on the walls of a PTFE knotted reactor. The sorbed species was eluted by isobutyl methyl ketone at a fl

Flow-injection on-line fibre column sepa
✍ Weiji Qi; Xing Wu; Chun Zhou; Haizhou Wu; Yingqi Gao 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 507 KB

A flow-injection on-line 8531 fibre column separation and preconcentration system is proposed for the efficient flame atomic absorption spectrometric determination of trace gold in ores and metallurgical samples. A flow manifold with a pump and two valves was assembled to conduct the operating cycle

Coupled flow-injection analysis-flame at
✍ Henryk J. Salacinski; Philip G. Riby; Stephen J. Haswell 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 577 KB

A method for determmmg the alunumum levels m local water, tea leaf digest, tea and coffee mfuslons by means of on-hne cation exchange flow-mlectlon-flame atomic absorptron spectrometry (FIA-FAAS) IS described Quantltatwe results can be carried out down to 7.5 ng ml -' of Al usmg sample volumes III t